Eaton 5P 5P850GR 850VA/600W 208-240V 1U Line Interactive Rackmount UPS
$788.90
Eaton 5P 5P850GR 850VA/600W 208-240V 1U Line Interactive Rackmount UPS
General | |
Topology | Line interactive |
Configuration | Rackmount / Wallmount |
Color | Black and silver |
Rating (VA/Watts) | 850/600 |
Diagnostics | Full system self-test at power up |
Dimensions (H x W x D, inches) | 1.7 (1U) x 17.2 x 20.0 |
Dimensions (H x W x D, mm) | 43.2 x 438 x 509 |
Weight (kg) | 13.8 |
Weight (lbs) | 30.4 |
Warranty | 3 years on electronics, 3 years on batteries with registration |
Rail Kit Included | 4-post rail kit |
Remote Emergency Power off (REPO) | ROO/RPO: Rear terminal block connector for remote on/off and power off |
Contents (Ships with the following items) |
5P UPS User manual CD Intelligent Power Software Suite CD Quick start guide USB cable RS-232 serial cable 4-post rail kit 2 IEC-to-IEC jumper cables Output cable locking system Input cable locking system |
Efficiency | up to 98% |
Electrical Input | |
Connection |
(1) IEC-320-C14
|
Input Voltage Range | 160-294Vac (adjustable to 150-294 Vac) |
Nominal Voltage | 230Vac (adjustable to 200/208/220/230/240 Vac) |
Frequency | 50/60 Hz (auto-sensing) |
Frequency Range | 47–70 Hz (50 Hz system), 56.5–70 Hz (60 Hz system), 40-70 Hz in low-sensitivity mode |
Electrical Output | |
Nominal Voltage | 230V default (200/208/220/230/240V) |
Output Receptacles |
(4) IEC-320-C13
|
On Utility Voltage Regulation | 184-256 Vac |
On Battery Voltage Regulation | -10%, +6% of nominal |
Output Frequency | 50/60 Hz ±0.1 % (autosensing) |
Load Segments | Group 1: (1) C13 outlet; Group 2: (1) C13 outlet view load segments application note |
Communications | |
User Interface | LCD graphical display |
LEDs | Load protected, on battery and fault |
Communication Ports | RS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included |
Communications Card Slots | One slot; Network Card-MS is optional |
Power Management Software | Eaton Intelligent Power Software Suite CD (included) |
Environmental & Standards | |
RoHS Compliance | Yes |
Heat Dissipation (BTU) | Line: 82, Battery 389 |
Audible Noise | <45 dB at 1 meter |
Operating Temperature | 0 to 35°C (32°F to 95°F) |
Performance - Safety - EMC | UL 1778, UL497A |
Safety markings | cULus, CE |
EMC Markings | IEC 62040-2 C1-C2 / EN 55024 / CISPR22 Class B / FCC part 15 Class B |
Storage Temperature | -15°C – 40°C (5°F – 104°F) |
Relative Humidity | 0–90% non-condensing |
Altitude | Up to 10,000 ft (3000m) without de-rating |
Recent News
How to Choose the Right UPS System for Your Business: A No-Nonsense Buyer’s Guide
Downtime is expensive. Whether you're running a data center, a healthcare facility, or a manufacturing line, power interruptions can disrupt operations and lead to major...
Hospital Emergency Backup Failures – Why Medical Facilities Can’t Afford a UPS Failure
In the high-stakes world of healthcare, seconds can save lives—or cost them. When power outages strike, hospitals and medical facilities rely heavily on uninterruptible power...
Why Your UPS Failed in a Heatwave—and How to Prevent It Next Time
When temperatures soar, the last thing you want is your uninterruptible power supply (UPS) giving up on you. Yet every summer, we hear the same...