Eaton 5P 5P750RC 750VA/600W 120V 2U Compact Line-interactive Rackmount UPS
$503.99
Eaton 5P 5P750RC 750VA/600W 120V 2U Compact Line-interactive Rackmount UPS
General | |
Topology | Line interactive |
Configuration | Rackmount / Wallmount |
Color | Black and silver |
Rating (VA/Watts) | 750/600 |
Diagnostics | Full system self-test at power up |
Dimensions (H x W x D, inches) | 3.4 (2U) x 17.3 x 16.0 |
Dimensions (H x W x D, mm) | 86.2 x 440 x 405 |
Weight (kg) | 14.1 |
Weight (lbs) | 31 |
Warranty | 3 years on electronics, 3 years on batteries with registration |
Rail Kit Included | Two-post rail kit, four-post rail kit, wall-mount kit |
Remote Emergency Power off (REPO) | ROO/RPO: Rear terminal block connector for remote on/off and power off |
Contents (Ships with the following items) |
5P rackmount compact UPS Quick start guide USB cable RS-232 serial cable Multi-purpose rail kit |
Efficiency | up to 95.8% |
Electrical Input | |
Connection |
(1) NEMA 5-15P
|
Input Cord | 6 feet (1.8 meters) |
Input Voltage Range | 89–151 Vac (adjustable to 70–153 Vac) |
Nominal Voltage | 120 Vac (adjustable to 100/120/125Vac) |
Frequency | 50/60 Hz (auto-sensing) |
Frequency Range | 47–70 Hz (50 Hz system), 56.5–70 Hz (60 Hz system), 40-70 Hz in low-sensitivity mode |
Electrical Output | |
Nominal Voltage | 120V default (100/120/125V) |
Output Receptacles |
(10) NEMA 5-15R
|
On Utility Voltage Regulation | 102–132 Vac |
On Battery Voltage Regulation | -10%, +6% of nominal |
Output Frequency | 50/60 Hz ±0.1 % (autosensing) |
Battery Description | Sealed, lead-acid; maintenance free |
Battery Management | ABM technology and temperature-compensated charging method (user selectable), automatic battery test and deep discharge protection |
Extended Battery Capability | None; See Eaton 5PX UPS for extended runtimes |
Start On Battery | Allows start of UPS without utility power (First time start must be on AC power) |
Communications | |
User Interface | LCD graphical display |
LEDs | Load protected, on battery and fault |
Communication Ports | RS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included |
Communications Card Slots | One slot; Gigabit Network Card (Network-M2) is optional |
Power Management Software | Eaton Intelligent Power Manager (included) |
Environmental & Standards | |
RoHS Compliance | Yes |
Heat Dissipation (BTU) | Line: 82, Battery 389 |
Audible Noise | <45 dB at 1 meter |
Operating Temperature | 0 to 35°C (32°F to 95°F) |
Performance - Safety - EMC | UL 1778, UL497A |
Safety markings | cULus, CE |
EMC Markings | IEC 62040-2 C1-C2 / EN 55024 / CISPR22 Class B / FCC part 15 Class B |
Storage Temperature | -15°C – 40°C (5°F – 104°F) |
Relative Humidity | 0–90% non-condensing |
Altitude | Up to 10,000 ft (3000m) without de-rating |