Eaton 5PX 5PX1500RT 1440VA/1440W 120V Rack/Tower Line Interactive UPS
Eaton 5PX 5PX1500RT 1440VA/1440W 120V Rack/Tower Line Interactive UPS
Eaton 5PX 5PX1500RT 1440VA/1440W 120V Rack/Tower Line Interactive UPS
Eaton 5PX 5PX1500RT 1440VA/1440W 120V Rack/Tower Line Interactive UPS
Eaton 5PX 5PX1500RT 1440VA/1440W 120V Rack/Tower Line Interactive UPS
Eaton 5PX 5PX1500RT 1440VA/1440W 120V Rack/Tower Line Interactive UPS
Eaton 5PX 5PX1500RT 1440VA/1440W 120V Rack/Tower Line Interactive UPS
Eaton 5PX 5PX1500RT 1440VA/1440W 120V Rack/Tower Line Interactive UPS
Eaton 5PX 5PX1500RT 1440VA/1440W 120V Rack/Tower Line Interactive UPS
Eaton 5PX 5PX1500RT 1440VA/1440W 120V Rack/Tower Line Interactive UPS
Eaton 5PX 5PX1500RT 1440VA/1440W 120V Rack/Tower Line Interactive UPS
Eaton 5PX 5PX1500RT 1440VA/1440W 120V Rack/Tower Line Interactive UPS
Eaton 5PX 5PX1500RT 1440VA/1440W 120V Rack/Tower Line Interactive UPS
Eaton 5PX 5PX1500RT 1440VA/1440W 120V Rack/Tower Line Interactive UPS

Eaton 5PX 5PX1500RT 1440VA/1440W 120V Rack/Tower Line Interactive UPS

$934.99 Sale Save

Only 0 left in stock

Eaton 5PX 5PX1500RT 1440VA/1440W 120V Rack/Tower Line Interactive UPS

General
Topology Line interactive
Configuration Rack/Tower
Catalog Number 5PX1500RT
Color Black
Rating (VA/Watts) 1440/1440
 
Diagnostics Full system self-test at power up
UPS Bypass EHBPL1500R-PDU1U (optional)
Dimensions (H x W x D, inches) 3.4 x 17.4 x 20.6
Dimensions (H x W x D, mm) 86 x 441 x 522
Weight (kg) 29
Weight (lbs) 65
Warranty 3 years on electronics, 3 years on batteries with registration
Rail Kit Included Tower stands and 4-post rail kit included
Contents
(Ships with the following items)
5PX1500RT
Four-post rail kit
User manual CD
Tower pedestals
Intelligent Power Software Suite CD
Quick start guide
RS-232 serial cable
USB cable
Phillips head screw driver
Electrical Input
Connection
(1) NEMA 5-15P

Input Cord 8 ft
Input Voltage Range 89–151 Vac (adjustable to 70–153 Vac)
Nominal Voltage 120 Vac (adjustable to100/120/127 Vac)
Frequency 50/60 Hz (auto-sensing)
Frequency Range 47–70 Hz (50 Hz system), 56.5–70 Hz (60 Hz system), 40 Hz in low-sensitivity mode
Input Power Factor 1
 
Electrical Output
Output Receptacles
(8) NEMA 5-15R
5-15R
On Utility Voltage Regulation 102–132 Vac
On Battery Voltage Regulation -10%, +6% of nominal
Output Frequency 50/60 Hz ±0.1 % (autosensing)
Transfer Time 1–4 ms typical
Load Segments Group 1: (2) 5-15R outlets Group 2: (2) 5-15R outlets
view load segments application note
​
Communications
User Interface LCD graphical display
LEDs Load protected, battery and fault
Communication Ports 1 USB HID compliant port + 1 RS232 serial port and relay contacts (USB and RS232 ports cannot be used simultaneously)
Communications Card Slots 1 slot for ConnectUPS-MS network management card
Power Management Software Eaton Intelligent Power Software Suite CD (included)
 
Environmental & Standards
Heat Dissipation (BTU) Line: 305, Battery: 2047
Audible Noise <45 dBA
Operating Temperature 0°C–40°C (32°F–104°F)
Performance - Safety - EMC UL1778; UL497A; cUL
Safety markings UL, cUL
EMC Markings FCC Part 15 subpart B Class A
Storage Temperature -15°C–50°C (5°F–122°F)
Relative Humidity 20–95% non-condensing
Altitude Up to 10,000 ft (3000m) without de-rating