Eaton 9PX 9PX6KP2 6kVA/5.4kW 208V-120/240 Hardwired In/Out UPS
$5,934.90
Eaton 9PX 9PX6KP2 6kVA/5.4kW 208V-120/240 Hardwired In/Out UPS
Eaton 9PX 9PX6KP2 Specifications:
General | |
Topology | Double-conversion online |
Configuration | Rack/Tower |
Catalog Number | 9PX6KP2 |
Color | Black and silver |
Rating (VA/Watts) | 6000/5400 |
Diagnostics | Full system self test at power up |
UPS Bypass | MBP6K208 optional. Rear-mount 3U, 208V maintenance bypass for 5 and 6 kVA 9PX UPS models. Hardwired input. Hardwired and (2) L6-30R output. |
Dimensions (H x W x D, inches) | 10.2 (6U) x 17.3 x 28.4 |
Dimensions (H x W x D, mm) | 259 (6U) x 439 x 721 |
Weight (kg) | 91 |
Weight (lbs) | 201 |
Warranty | 2 years |
Rail Kit Included | 4-post rail kit and tower pedastals included |
Remote Emergency Power off (REPO) | ROO/RPO: Rear deck emergency stop connectors (for remote on/off and power off) |
Contents (Ships with the following items) |
9PX6K 6 kVA 3U UPS 9PXPPDM2 HW PowerPass Distribution Module Gigabit Network card (Network-M2) 4-post rail kit User manual Quick start guide Tower pedestals Intelligent Power Software Suite CD RS-232 serial cable USB cable Cable gland for hardwire connection Phillips head screw driver |
Efficiency | 93% with resistive load |
Electrical Input | |
Connection |
Hardwired - see manual for terminal block layout
|
Input Cord | None; hardwired |
Input Voltage Range | Full load: 176-276V, Derating: 100-276V |
Nominal Voltage | 208V default (200/208/220/230/240V) |
Frequency | 50/60 Hz |
Frequency Range | 60 Hz: 50–70 Hz, 50 Hz: 40–60 Hz |
Input Power Factor | >99 |
Input Current Distortion | <5% |
Electrical Output | |
Nominal Voltage | 120/240V default (200/208/220/230/240V) |
Output voltage regulation | ±1% steady-state |
Voltage THD | <2% for linear loads |
Output Receptacles |
Hardwired - see manual for terminal block layout
|
Power Factor | 0.9 |
Transfer Time | 0 ms |
Circuit Breaker | (1) 30A |
Optional Extended Battery Module | 9PXEBM180RT |
Battery Description | Sealed, lead-acid; maintenance free |
Maximum number of extended battery modules (EBM) | Add up to 4 extended battery modules (EBM) |
Battery Management | ABM technology; 3-stage charging extends battery service life by 50% and provides advance warning for battery replacement |
Battery Replacement | Hot-swappable internal batteries and extended battery modules (EBMs) |
Start On Battery | Cold-start enabled; first cold start is always forbidden |
Communications | |
User Interface | Graphical display. UPS status in a single view. |
LEDs | 4 status-indicating LEDs |
Communication Ports | RS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included |
Communications Card Slots | Gigabit Network Card (Network-M2) included |
Power Management Software | Eaton Intelligent Power Software Suite CD (included) |
Environmental & Standards | |
RoHS Compliance | Yes |
Surge Protection | IEEE ANSI C62.41 Cat B2 |
Audible Noise | <45 dB at 1 meter |
Operating Temperature | 0 to 40°C (32°F to 104°F) |
Safety markings | CE / cULus / NOM |
EMC Markings | IEC 62040-2:2006 Cat C2 / CISPR22 Class A / FCC part 15 Class A |
Storage Temperature | 0 to 35°C (32°F to 95°F); without batteries: -15 to 60°C (5°F to 140°F) |
Relative Humidity | 0 to 95% |
Altitude | <1,000 meters for nominal power; 10% power derating every 1000 meters (up to 3000 meters) |