Vertiv Liebert GXT5-1500LVRT2UXL 1500VA 1350W 120V Online Rack/Tower UPS
$1,399.90
The Vertiv™ Liebert® GXT5 UPS, with a capacity of 1500VA/1350W, is a 2U compact and efficient UPS solution for ensuring the health and availability of IT infrastructure. With online, double conversion technology, the Vertiv Liebert GXT5 UPS protects critical equipment against outages and every type of power disturbance without drawing on battery power, extending battery life and minimizing replacements.
Key Benefits of the Vertiv™ Liebert® GXT5 UPS:
- Enhanced local and remote management capabilities enable users to understand the condition of the critical infrastructure space and take action when necessary
- High power factor operation up to unity provides the highest available power (watt) for use by connected IT equipment, allowing for more connected devices
- Integrated serial connection for advanced console server integration or direct terminal control of the UPS
- Energy Star® 2.0 certification with efficiency in online (95%) and Active ECO (98%) modes
- SNMP network communications with optional Liebert® RDU101 NIC and free Trellis™ Power Insight
- Gravity-sensing, color LCD for easy configuration and system diagnosis
- Scalable power with auto-detection of external battery cabinets
- Connected Equipment Protection Plan
Liebert GXT5-1500LVRT2UXL UPS Specifications
Mechanical | |
Height | 3.4" (85 mm.) |
Width | 16.9" (430 mm.) |
Depth | 18.5" (470 mm.) |
Weight | 46.2 lb (21 kg) |
Rack Height | 2U |
Color | Black |
Input AC | |
Range | Typical 120V Range: 60-150V |
Frequency | 40-70Hz; Auto Sensing |
Input Power Cord | 10 ft. attached w/ NEMA 5-15P A plug |
Output AC | |
Output Receptacles | 6 x 5-15R |
Voltage | Typical 120V 110/115/120VAC (user-configurable); ±3% |
Waveform | Sine wave |
Utility (AC) Mode Overload | >200% for 250ms; 150- 200% for 2 seconds 125- 150% for 50 seconds; 105-125% for 60 seconds |
Battery | |
Type | Valve-regulated, non-spillable, lead acid |
Backup Time | 6.7 Minutes (100% Load) 18.8 Minutes(50% Load) |
+1 External Battery Cabinet | 32.4 Minutes (100% Load) 79.7 Minutes(50% Load) |
Environmental | |
Operating Temperature | 32 to 104°F (0 to 40°C) |
Storage Temperature | -4 to 140°F (-20 to 60°C) |
Relative Humidity | 0% to 95%, non-condensing |
Operating Elevation | 10,000 ft. (3,000m) |
Storage Elevation | 50,000 ft. (15,000m) |
Audible Noise | < 46dBA max @ 3 ft. (1m) front and sides < 43dBA, at 3 ft. (1m) rear |
Agency | |
Surge Immunity | ANSI C62.41 Category B |
Transportation | ISTA Procedure 1A |
Safety | UL 1778 4th Edition and CSA 22.2 No. 107.3 |
Emissions | FCC Part 15 (Class A) - CISPR22 Class A (RFI) |
Warranty |
3 year warranty (Opt. 2 year) |