Eaton 9155 10kVA 9kW 32-Battery 2-High Hardwired In/Out Tower UPS
Eaton 9155 10kVA 9kW 32-Battery 2-High Hardwired In/Out Tower UPS
Eaton 9155 10kVA 9kW 32-Battery 2-High Hardwired In/Out Tower UPS
Eaton 9155 10kVA 9kW 32-Battery 2-High Hardwired In/Out Tower UPS

Eaton 9155 10kVA 9kW 32-Battery 2-High Hardwired In/Out Tower UPS

$12,769.90 Sale Save

Only 2 left in stock

The Eaton 9155 UPS provides premium online backup power and scalable battery runtimes for IT and electrical engineering infrastructure in corporate, healthcare, banking and industrial applications. Packing maximum battery runtime into a very small footprint, the 9155 UPS is a complete power protection solution. The 9155 can be equipped with an integrated, customizable power distribution module that includes a maintenance bypass switch.

General
Topology Double-conversion
Catalog Number K41011000000000
Part Number K41011000000000
Color Black
Rating (VA/Watts) 10000/9000
 
Diagnostics Full system self-test at startup
UPS Bypass Automatic on overload or UPS failure
Dimensions (H x W x D, inches) 32.2 x 12 x 33.7
Weight (lbs) 352
Warranty Two-year factory warranty
Contents
(Ships with the following items)
1 ready-to-go UPS
Software Suite CD
User Guide
Efficiency 92% with nominal linear load; 91% with nominal computer load.
 
Electrical Input
Connection
Hardwired - see manual for terminal block layout
Frequency 50/60 Hz (45 to 65 Hz)
Frequency Range 45 to 65 Hz
Input Power Factor P.F >0.99 typical, >0.96 frequency converter
Generator Compatability Yes
 
Electrical Output
100/200, 110/220, 120/240 Vac 180° phase displacement; 120/208, 127/220 Vac 120° phase displacement
Output Receptacles
Hardwired (PDM Optional)
On Utility Voltage Regulation Output voltage regulation ±1% Static; ±5% dynamic at 100% resistive load change
On Battery Voltage Regulation Output voltage regulation ±1% Static; ±5% dynamic at 100% resistive load change
Overload Capacity 150% for 5 sec / 125% for 1 min (online), 110% for 10 min
Voltage Wave Shape (On Battery) Sine Wave
Transfer Time 0 ms
 
Battery
 
Battery Management ABM technology
Battery Type 9Ah, sealed, lead-acid, maintenance-free
Battery Replacement Field-replaceable
Start On Battery Allows start of UPS without utility input
Recharge Time Internal battery: approximately 3 hours to 80% usable capacity at nominal line voltage after full load discharge External battery: no more than 10x discharge time to 90% usable capacity at nominal line voltage after full load discharge
 
Communications
User Interface LCD Display with blue backlight
LEDs (4) LEDs for notice and alarm
Audible Alarms Yes
Communication Ports (1) RS-232, (1) relay contact, (1) REPO, (2) environmental input
Communication Slot (2) X-Slot communication bays
Power Management Software Bundled Software Suite CD
 
Environmental & Standards
Audible Noise <53dBA at 1 meter (noise less room) typical
Operating Temperature 10°C to +40°C, +45°C with 7.5% derating; Batteries recommended max. +25�C
Markings UL, cUL, CSA, CE and NOM-NYCE
Storage Temperature -15°C to +25°C
Relative Humidity 0-95%, non condensing