Eaton 9PX 9PX2000RT 2000VA/1800W 120V Online Double Conversion Rack / Tower UPS
Eaton 9PX 9PX2000RT 2000VA/1800W 120V Online Double Conversion Rack / Tower UPS
Eaton 9PX 9PX2000RT 2000VA/1800W 120V Online Double Conversion Rack / Tower UPS
Eaton 9PX 9PX2000RT 2000VA/1800W 120V Online Double Conversion Rack / Tower UPS
Eaton 9PX 9PX2000RT 2000VA/1800W 120V Online Double Conversion Rack / Tower UPS
Eaton 9PX 9PX2000RT 2000VA/1800W 120V Online Double Conversion Rack / Tower UPS
Eaton 9PX 9PX2000RT 2000VA/1800W 120V Online Double Conversion Rack / Tower UPS
Eaton 9PX 9PX2000RT 2000VA/1800W 120V Online Double Conversion Rack / Tower UPS
Eaton 9PX 9PX2000RT 2000VA/1800W 120V Online Double Conversion Rack / Tower UPS
Eaton 9PX 9PX2000RT 2000VA/1800W 120V Online Double Conversion Rack / Tower UPS
Eaton 9PX 9PX2000RT 2000VA/1800W 120V Online Double Conversion Rack / Tower UPS
Eaton 9PX 9PX2000RT 2000VA/1800W 120V Online Double Conversion Rack / Tower UPS

Eaton 9PX 9PX2000RT 2000VA/1800W 120V Online Double Conversion Rack / Tower UPS

$1,724.90 Sale Save

Only 5 left in stock

Eaton 9PX 9PX2000RT 2000VA/1800W 120V Online Double Conversion Rack / Tower UPS 
Eaton 9PX 9PX2000RT Specifications:
General
Topology Double-conversion online
Configuration Rack/Tower
Catalog Number 9PX2000RT
Color Black and silver
Rating (VA/Watts) 2000/1800
 
Diagnostics Full system self test at power up, and ABM test every 30 days
UPS Bypass EHBPL2000R-PDU1U optional
Dimensions (H x W x D, inches) 3.4 (2U) x 17.3 x 23.8
Dimensions (H x W x D, mm) 86.5 x 440 x 605
Weight (kg) 27.9
Weight (lbs) 61.5
Warranty 2 years
Rail Kit Included 4-post rail kit and tower pedestals included
Remote Emergency Power off (REPO) ROO/RPO: Rear deck emergency stop connectors (for remote on/off and power off)
Contents
(Ships with the following items)
9PX2000RT 2 kVA UPS
4-post rail kit
Safety manual
User manual
Tower pedestals
RS-232 serial cable
USB cable
Intelligent Power Software Suite CD
Efficiency 91% with resistive load
 
Electrical Input
Connection
(1) NEMA 5-20P

Input Cord 8 feet
Input Voltage Range Full load: 100-144V, <30% load: 60-144V
Nominal Voltage 120V default (100/110/120/125V)
Frequency 50/60 Hz
Frequency Range 60 Hz: 50–70 Hz, 50 Hz: 40–60 Hz
Input Power Factor >.99
Input Current Distortion <5%
 
Electrical Output
Nominal Voltage 120V default (100/110/120/125V)
Output voltage regulation ±1% steady-state
Voltage THD <3% for linear loads
Output Receptacles
(6) NEMA 5-20R

(1) NEMA L5-20R

Transfer Time 0 ms
Communications
User Interface Graphical display. UPS status in a single view.
LEDs 4 status-indicating LEDs
Communication Ports RS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included
Power Management Software Eaton Intelligent Power Manager
 
Environmental & Standards
RoHS Compliance Yes
Surge Protection IEEE ANSI C62.41 Cat B2
Heat Dissipation (BTU) Online: 578
Battery: 974
(BTU/hr; battery full charged, resistive load)
Audible Noise ≤47 dB at 1 meter
Operating Temperature 0 to 40°C (32°F to 104°F)
Safety markings CE / cULus / NOM
EMC Markings IEC 62040-2 Cat C1 / CISPR22 / FCC part 15 Class B / VCCI Class B
Storage Temperature 0 to 35°C (32°F to 95°F); without batteries: -15 to 55°C (5°F to 131°F)
Relative Humidity 0 to 96% non-condensing
Altitude 3000m