Eaton 9PX 9PX8KSP 8kVA/7.2kW 120/208V Split Phase Online Rack/Tower UPS
$6,917.90
Eaton 9PX 9PX8KSP 8kVA/7.2kW 120/208V Split Phase Online Rack/Tower UPS
Eaton 9PX 9PX8KSP Specifications:
General | |
Topology | Double-conversion online |
Configuration | Rack/Tower |
Catalog Number | 9PX8KSP |
Color | Black and silver |
Rating (VA/Watts) | 8000/7200 |
Diagnostics | Full system self test at power up |
UPS Bypass | MBP11K208 optional. Rear-mount 3U, 208V maintenance bypass for 8 and 11 kVA 9PX UPS models. Hardwired input. Hardwired and (3) L6-30R output |
Dimensions (H x W x D, inches) | 10.3 (6U) x 17.3 x 32.0 |
Weight (lbs) | 225 |
Warranty | 2 years |
Rail Kit Included | 4-post rail kit and tower pedastals included |
Remote Emergency Power off (REPO) | ROO/RPO: Rear deck emergency stop connectors (for remote on/off and power off) |
|
|
Electrical Input | |
Connection |
Hardwired - see manual for terminal block layout
|
Input Cord | None; hardwired |
Input Voltage Range | Full load: 176-276V; Derating: 100-276V |
Nominal Voltage | 120/208 default (120/240, 100/200, 110/220, 115/230, 127/220) |
Frequency | 50/60 Hz |
Frequency Range | 60 Hz: 50–70 Hz, 50 Hz: 40–60 Hz |
Input Power Factor | >99 |
Input Current Distortion | <5% |
Electrical Output | |
Nominal Voltage | 120/208 default (120/240, 100/200, 110/220, 115/230, 127/220) |
Output voltage regulation | ±1% steady-state |
Voltage THD | <2% for linear loads |
Output Receptacles |
(1) NEMA L6-30R
(2) NEMA L14-30R
Hardwired - see manual for terminal block layout
|
Power Factor | 0.9 |
Transfer Time | 0 ms |
Circuit Breaker | (1) 30A for l6-30R; (2) 30A for L14-30R |
Battery | |
Optional Extended Battery Module | 9PXEBM360SP |
Battery Description | Sealed, lead-acid; maintenance free |
Maximum number of extended battery modules (EBM) | Add up to 4 extended battery modules (EBM) |
Battery Management | ABM technology; 3-stage charging extends battery service life by 50% and provides advance warning for battery replacement |
Battery Replacement | Hot-swappable internal batteries and extended battery modules (EBMs) |
Start On Battery | Cold-start enabled |
Communications | |
User Interface | Graphical display. UPS status in a single view. |
LEDs | 4 status-indicating LEDs |
Communication Ports | RS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included |
Communications Card Slots | Gigabit Network Card (Network-M2) included |
Power Management Software | Eaton Intelligent Power Software Suite CD (included) |