Eaton 9PX 9PX3000RTN 3000VA/2700W 120V Online Rack / Tower UPS w/Network Option
Eaton 9PX 9PX3000RTN Specifications:
General |
Topology |
Double-conversion online |
Configuration |
Rack/Tower |
Catalog Number |
9PX3000RTN |
Color |
Black and silver |
Rating (VA/Watts) |
3000/2700 |
|
|
Diagnostics |
Full system self test at power up, and ABM test every 30 days |
UPS Bypass |
EHBPL3000R-PDU1U optional |
Dimensions (H x W x D, inches) |
3.4 (2U) x 17.3 x 23.8 |
Dimensions (H x W x D, mm) |
86.5 x 440 x 605 |
Weight (kg) |
28.6 |
Weight (lbs) |
63.1 |
Warranty |
2 years |
Rail Kit Included |
4-post rail kit and tower pedestals included |
Remote Emergency Power off (REPO) |
ROO/RPO: Rear deck emergency stop connectors (for remote on/off and power off) |
Contents (Ships with the following items) |
9PX3000RTN 3 kVA UPS Gigabit Network card (Network-M2) 4-post rail kit Safety manual User manual Tower pedestals RS-232 serial cable USB cable Intelligent Power Software Suite CD
|
Efficiency |
91% with resistive load |
|
Electrical Input |
Connection |
|
Input Cord |
8 feet |
Input Voltage Range |
Full load: 100-144V, <30% load: 60-144V |
Nominal Voltage |
120V default (100/110/120/125V) |
Frequency |
50/60 Hz |
Frequency Range |
60 Hz: 50–70 Hz, 50 Hz: 40–60 Hz |
Input Power Factor |
>.99 |
Input Current Distortion |
<5% |
|
Electrical Output |
Nominal Voltage |
120V default (100/110/120/125V) |
Output voltage regulation |
±1% steady-state |
Voltage THD |
<3% for linear loads |
Output Receptacles |
|
Transfer Time |
0 ms |
Circuit Breaker |
(2) 20A for 5-20R |
Optional Extended Battery Module |
9PXEBM72RT |
Battery Description |
Sealed, lead-acid; maintenance free |
Maximum number of extended battery modules (EBM) |
Add up to 4 extended battery modules (EBM) |
Battery Management |
ABM technology; 3-stage charging extends battery service life by 50% and provides advance warning for battery replacement |
Battery Replacement |
Replaceable internal batteries and extended battery modules (EBMs) |
Start On Battery |
Cold-start enabled; first cold start is always forbidden |
|
Communications |
User Interface |
Graphical display. UPS status in a single view. |
LEDs |
4 status-indicating LEDs |
Communication Ports |
RS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included |
Communications Card Slots |
Gigabit Network Card (Network-M2) included |
Power Management Software |
Eaton Intelligent Power Manager |
|
Environmental & Standards |
RoHS Compliance |
Yes |
Surge Protection |
IEEE ANSI C62.41 Cat B2 |
Heat Dissipation (BTU) |
Online: 844 Battery: 1462 (BTU/hr; battery full charged, resistive load) |
Audible Noise |
≤47 dB at 1 meter |
Operating Temperature |
0 to 40°C (32°F to 104°F) |
Safety markings |
CE / cULus / NOM |
EMC Markings |
IEC 62040-2 Cat C1 / CISPR22 / FCC part 15 Class B / VCCI Class B |
Storage Temperature |
0 to 35°C (32°F to 95°F); without batteries: -15 to 55°C (5°F to 131°F) |
Relative Humidity |
0 to 96% non-condensing |
Altitude |
3000m |