MGE Galaxy 4000 65kVA UPS System and Battery Cabinet (208V)
$4,720.90
The MGE Galaxy 4000 - robust 3 phase UPS power protection designed for flexibility in order to meet a wide range of requirements from medium data centers to industrial and facilities applications.
Specifications
• Model No: 72-173008-00 (65 kVA)
• UPS Input: 208VAC, 3PH, 4W, G, 60HZ, 166A
• UPS Output: 208VAC, 3PH, 4W, G, 60HZ, 180A
• Battery: 198-282VDC, 255A at 240VDC
• Model No: 72-173008-00 (65 kVA)
• UPS Input: 208VAC, 3PH, 4W, G, 60HZ, 166A
• UPS Output: 208VAC, 3PH, 4W, G, 60HZ, 180A
• Battery: 198-282VDC, 255A at 240VDC
• Weight: 1,235 lbs
Double conversion online topology
• True isolation between the input and output
• Independence of the input and output voltages and frequency
• No-break transfer to battery or bypass power
• Does not rely on the batteries for frequency stabilization
• True isolation between the input and output
• Independence of the input and output voltages and frequency
• No-break transfer to battery or bypass power
• Does not rely on the batteries for frequency stabilization
Dual mains input/output
• Allows for top or bottom feed connection to two separate power inputs for increased availability
• Allows for top or bottom feed connection to two separate power inputs for increased availability
Input power factor correction
• Eliminates harmful distortion that is reflected back onto the utility from the UPS from disturbing sensitive equipment sharing the utility power
• Eliminates harmful distortion that is reflected back onto the utility from the UPS from disturbing sensitive equipment sharing the utility power
Digital power quality management
• Output created from hundreds of variable width pulses (pulse width modulation)
• Control loop compares output to a references sine wave and makes adjustments or correction pulses to maintain a “power quality envelope”
• Output created from hundreds of variable width pulses (pulse width modulation)
• Control loop compares output to a references sine wave and makes adjustments or correction pulses to maintain a “power quality envelope”
Fault tolerant circuitry
• Fast current limiting avoids overloading the inverter, while the robust static bypass switch feeds enough utility power to clear the fault, resulting in a load that will stay protected and a UPS that will remain intact
• Fast current limiting avoids overloading the inverter, while the robust static bypass switch feeds enough utility power to clear the fault, resulting in a load that will stay protected and a UPS that will remain intact
System professionally tested & load banked and verified working unit. Cabinet(s) may show wear from previous installation and removal.
(Batteries NOT Included but can be added for additional cost upon request)
NOTE: Wiring and startup of system by trained/certified professional required
Recent News
How UPS Battery Backups Help Reduce Energy Costs
Energy efficiency isn't just about sustainability, it’s about cost savings. Companies across industries are looking for ways to reduce their electricity bills without compromising uptime...
Lighting Inverters: Ensuring Uninterrupted Safety and Compliance for Emergency Systems
What is a Lighting Inverter? A lighting inverter converts DC battery power to standard AC voltages to provide backup for lighting systems during...
From Power Outages to Business Continuity: How UPS Systems Save the Day
Businesses can't afford unexpected power outages. Even a brief disruption can lead to lost productivity, corrupted data, and decreased customer satisfaction. That's where Uninterruptible...