Toshiba 4400 Series 80kVA 208VAC 3-Phase UPS / 2019 (4400F3F800XA)

$33,250.40 Sale Save $3,694.50

Only 1 left in stock

Adding to Cart Added to Cart

The Toshiba 4400 Series uninterruptible power system (UPS) is the next-generation 3 phase UPS. The double-conversion, all insulated-gate bipolar transistor (IGBT) 4400 Series UPS features a digitally controlled IGBT input rectifier, an intelligent low harmonic pulse-width modulation (PWM) output, state-of-the-art electronic battery isolation circuitry, and an easy to navigate local touchscreen interface.

The 4400 3 Phase Uninterruptible Power Supply (UPS) utilizes double-conversion, all insulated-gate bipolar transistors (IGBT) technology.  Ideal for generators with wide voltage and frequency input window without utilizing batteries. 4400 Series UPS systems are ideal for data centers and easy to install and customize for multiple markets and applications.

 

Input
Standard Voltage 208V
Phase 3PH
Frequency 50/60Hz
Power Factor 0.98
DC Voltage 288V

 

Output
Standard Voltage 208V
Phase 3PH
Frequency 50/60HZ
Power Factor 0.9
Voltage THD <3% THD at full linear load
Overload Capacity 109% Continuous, 110-124% for 6 Minutes, 125-149% for 90 Seconds, 150% for 30 Seconds;

 

Environment
Temperature Range 32° to 104°F (0° to 40°C)
Humidity 0-95%, non-condensing
Heat Rejection 24,297 BTU/Hr
Full-Load Efficiency 0.92
Altitude 3300 ft (1000 m) above sea level
Audible Noise 63dBA @ 1 m Typical

 

Dimensions
Dimensions 32.1" W x 37.2" D x 73.8" H
Weight 1550lbs.

 

 

NOTES:

Unit is NEW, never installed, fully tested and certified.

Some minor external damage (See photos for details)

System requires battery cabinet and batteries for operation - not included.  (Pricing and lead-time available upon request)

Wiring and startup of system by trained/certified professional required.

Recent News

Spring Facility Check: Don’t Forget Your Lighting Inverter

Spring Facility Check: Don’t Forget Your Lighting Inverter

  As winter begins to fade and facilities start their spring maintenance routines, many teams focus on HVAC systems, generators, and electrical inspections. While these...

Read more
AI Is Changing Power Demands: Is Your UPS Infrastructure Ready?

AI Is Changing Power Demands: Is Your UPS Infrastructure Ready?

 {"height":13,"color":{"hue":213,"brightness":0.83,"saturation":1,"alpha":0},"hidden":false,"locked":false,"blockName":"Spacer"} Artificial intelligence isn’t just impacting hyperscale data centers. It’s changing power infrastructure requirements across mid-sized data centers, healthcare facilities, manufacturing plants, and enterprise IT...

Read more
The Real Difference Between Entry-Level, Mid-Range, and Enterprise UPS Systems

The Real Difference Between Entry-Level, Mid-Range, and Enterprise UPS Systems

    Choosing the right Uninterruptible Power Supply (UPS) isn’t just about size or price, it’s about matching the right level of protection to your...

Read more