




APC Smart-UPS Ultra On-Line 5000VA/4900W Rack/Tower Lithium-ion UPS (SRTL5KRM2UT)
With Smart-UPS Ultra you can put power protection in places never before possible. At half the size and weight of comparable UPS available on the market today, the mounting brackets can be used in any of the 4 mounting styles: rack, tower, wall and ceiling/ desk under mount. The auto-rotating touch screen display makes switching between horizontal and vertical mounting options instantaneous.
Designed for local edge environments and micro data centers, the Smart-UPS Ultra provides consistent and reliable connectivity at the most critical moments. The UPS’s light and compact size allow for installation on the wall or ceilings for top-tier flexibility. Increased UPS battery life and lower maintenance service costs provide a lower total cost of ownership over 10 years.
Highlights:
- 5kVA/4.9kW double-conversion on-line pure sine wave 2U rackmount UPS
- Add up to 10 external battery packs (SRTL180RM2UBP) for extended runtime
- Rack/Tower convertible (rail kit included)
- Graceful shutdown of physical servers, virtual machines and HCI Clusters
- Lithium-ion battery minimizes the need to replace battery during the life time of UPS
Specifications:
| Model |
SRTL5KRM2UT |
| GTIN |
731304435730 |
| Topology |
Double Conversion Online |
| Voltage |
208V |
| Power rating |
5000VA/4900W |
| Input connection |
NEMA L6-30P |
| Output connection |
(2) NEMA L6-20R & (2) NEMA L6-30R |
| Number of rack units |
2U |
| Battery type |
Lithium-ion |
| Bypass type | Internal Bypass (Automatic and Manual) |
| Wave type |
Sine wave |
| Package contents |
|
| Typical recharge time |
1.5 h |
| Battery voltage |
180V |
| Battery charge power |
600 W |
| Dimensions (HxWxD) |
3.39 x 17.01 x 27.60 in |
| Weight |
64.38 lbs |
| Warranty |
5 years |
Recent News
Single-Phase vs. Three-Phase UPS: What Growing Businesses Get Wrong
As businesses grow, so do their power demands. What once worked for a small server room or office network can quickly become inadequate as more...
How Heat Affects Data Centers and Why Your UPS System Is at Risk
As temperatures rise and computing demands continue to grow, heat has become one of the most serious threats facing modern data centers, server rooms, and...
Spring Facility Check: Don’t Forget Your Lighting Inverter
As winter begins to fade and facilities start their spring maintenance routines, many teams focus on HVAC systems, generators, and electrical inspections. While these...