




APC Symmetra PX SYPM25KD 25kVA/25kW 480V Power Module (Preowned)
* Preowned APC Symmetra PX SYPM25KD 25kVA / 25kW 480V Power Module
Recently removed from operational system. Fully tested for functionality.
Technical Specifications:
Output
- Max Configurable Power (Watts): 25.0kWatts / 25.0kVA
- Efficiency at Full Load: 96.0 %
- Output Voltage Distortion: Less than 2%
- Output Frequency (not synced): 60Hz +/- 0.1% for 60Hz nominal, 50Hz +/- 0.1% for
- 50Hz nominal
- Load Crest Factor: Unlimited
- Topology: Double Conversion Online
- Waveform type: Sine wave
- Overload Operation: 10 minutes @ 125% and 60 seconds @ 150%
- Output Voltage THD: < 2% for 0 to 100% linear load and < 6% for full non linear load
- Output Voltage Tolerance: +/-1% static and +/- 5% at 100% load step
Input
- Input frequency: 40 - 70 Hz
- Input voltage range for main operations: 340 - 460 (400V), 408 - 552 (480)V
- Efficiency at Full Load: 96.0 %
- Input Total Harmonic Distortion: Less than 5% for full load
- Input Power Factor at Full Load: 0.99
Physical
- Maximum Height: 6.81inches (173MM, 17.3CM)
- Maximum Width: 17.8inches (452MM, 45.2CM)
- Maximum Depth: 27.76inches (705MM, 70.5CM)
- Net Weight: 92.4lbs. (42.0KG)
- Shipping weight: 106.0lbs. (48.18KG)
- Shipping Height: 11.22inches (285MM, 28.5CM)
- Shipping Width: 23.03inches (585MM, 58.5CM)
- Shipping Depth: 36.81inches (935MM, 93.5CM)
- Color: Black
- Units per Pallet: 6.0
Environmental
- Operating Temperature: 32 - 104 °F (0 - 40 °C)
- Operating Relative Humidity: 0 - 95 %
- Operating Elevation: 0-3333ft (0-999.9meters)
- Storage Temperature: -15 - 40 °C
- Storage Relative Humidity: 0 - 95 %
- Storage Elevation: 0-50000ft (0-15000meters)
- Audible noise at 1 meter from surface of unit: 54.0dBA
- Approvals: cUL Listed, CE, UL Listed, VDE
- Sustainable Offer Status: RoHS Compliant
Recent News
Single-Phase vs. Three-Phase UPS: What Growing Businesses Get Wrong
As businesses grow, so do their power demands. What once worked for a small server room or office network can quickly become inadequate as more...
How Heat Affects Data Centers and Why Your UPS System Is at Risk
As temperatures rise and computing demands continue to grow, heat has become one of the most serious threats facing modern data centers, server rooms, and...
Spring Facility Check: Don’t Forget Your Lighting Inverter
As winter begins to fade and facilities start their spring maintenance routines, many teams focus on HVAC systems, generators, and electrical inspections. While these...