Technical Specifications:
Output
- Max Configurable Power (Watts): 25.0kWatts / 25.0kVA
- Efficiency at Full Load: 96.0 %
- Output Voltage Distortion: Less than 2%
- Output Frequency (not synced): 60Hz +/- 0.1% for 60Hz nominal, 50Hz +/- 0.1% for
- 50Hz nominal
- Load Crest Factor: Unlimited
- Topology: Double Conversion Online
- Waveform type: Sine wave
- Overload Operation: 10 minutes @ 125% and 60 seconds @ 150%
- Output Voltage THD: < 2% for 0 to 100% linear load and < 6% for full non linear load
- Output Voltage Tolerance: +/-1% static and +/- 5% at 100% load step
Input
- Input frequency: 40 - 70 Hz
- Input voltage range for main operations: 340 - 460 (400V), 408 - 552 (480)V
- Efficiency at Full Load: 96.0 %
- Input Total Harmonic Distortion: Less than 5% for full load
- Input Power Factor at Full Load: 0.99
Physical
- Maximum Height: 6.81inches (173MM, 17.3CM)
- Maximum Width: 17.8inches (452MM, 45.2CM)
- Maximum Depth: 27.76inches (705MM, 70.5CM)
- Net Weight: 92.4lbs. (42.0KG)
- Shipping weight: 106.0lbs. (48.18KG)
- Shipping Height: 11.22inches (285MM, 28.5CM)
- Shipping Width: 23.03inches (585MM, 58.5CM)
- Shipping Depth: 36.81inches (935MM, 93.5CM)
- Color: Black
- Units per Pallet: 6.0
Environmental
- Operating Temperature: 32 - 104 °F (0 - 40 °C)
- Operating Relative Humidity: 0 - 95 %
- Operating Elevation: 0-3333ft (0-999.9meters)
- Storage Temperature: -15 - 40 °C
- Storage Relative Humidity: 0 - 95 %
- Storage Elevation: 0-50000ft (0-15000meters)
- Audible noise at 1 meter from surface of unit: 54.0dBA
- Approvals: cUL Listed, CE, UL Listed, VDE
- Sustainable Offer Status: RoHS Compliant
Recent News
AI Is Changing Power Demands: Is Your UPS Infrastructure Ready?
{"height":13,"color":{"hue":213,"brightness":0.83,"saturation":1,"alpha":0},"hidden":false,"locked":false,"blockName":"Spacer"} Artificial intelligence isn’t just impacting hyperscale data centers. It’s changing power infrastructure requirements across mid-sized data centers, healthcare facilities, manufacturing plants, and enterprise IT...
The Real Difference Between Entry-Level, Mid-Range, and Enterprise UPS Systems
Choosing the right Uninterruptible Power Supply (UPS) isn’t just about size or price, it’s about matching the right level of protection to your...
Strategic UPS Upgrades: Strengthening Power Protection for Your Critical Operations
A reliable UPS system is more than backup power—it’s a core part of your infrastructure strategy. As power demands grow and downtime becomes more...