Eaton 9155 12kVA 10.8kW 32-Battery 2-High Hardwired In/Out Tower UPS 2yr Warranty
Eaton 9155 12kVA 10.8kW 32-Battery 2-High Hardwired In/Out Tower UPS 2yr Warranty
The Eaton 9155 UPS provides premium online backup power and scalable battery runtimes for IT and electrical engineering infrastructure in corporate, healthcare, banking and industrial applications. Packing maximum battery runtime into a very small footprint, the 9155 UPS is a complete power protection solution. The 9155 can be equipped with an integrated, customizable power distribution module that includes a maintenance bypass switch.
General
- Topology: Double-conversion
- Catalog Number: K41211000000000
- Part Number: K41211000000000
- Color: Black
- Rating (VA/Watts): 12000/10800
- Diagnostics: Full system self-test at startup
- UPS Bypass: Automatic on overload or UPS failure
- Dimensions (H x W x D, inches): 32.2 x 12 x 33.7
- Weight (lbs): 558
- Warranty: Two-year factory warranty
- Contents: 1 ready-to-go UPS, Software Suite CD, & User Guide
- Efficiency 92% with nominal linear load; 91% with nominal computer load.
Electrical Input
- Connection: Hardwired - see manual for terminal block layout
- Frequency: 50/60 Hz (45 to 65 Hz)
- Frequency Range: 45 to 65 Hz
- Input Power Factor: P.F >0.99 typical, >0.96 frequency converter
- Generator Compatibility: Yes
Electrical Output
- Output: 100/200, 110/220, 120/240 Vac 180° phase displacement; 120/208, 127/220 Vac 120° phase displacement
- Output Connection(s): Hardwired
- On Utility Voltage Regulation: Output voltage regulation ±1% Static; ±5% dynamic at 100% resistive load change
- On Battery Voltage Regulation: Output voltage regulation ±1% Static; ±5% dynamic at 100% resistive load change
- Overload Capacity: 150% for 5 sec / 125% for 1 min (online), 110% for 10 min
- Voltage Wave Shape (On Battery): Sine Wave
- Transfer Time: 0 ms
Battery
- Battery Management: ABM technology
- Battery Type: 9Ah, sealed, lead-acid, maintenance-free
- Battery Replacement: Field-replaceable
- Start On Battery: Allows start of UPS without utility input
- Recharge Time: Internal battery: approximately 3 hours to 80% usable capacity at nominal line voltage after full load discharge External battery: no more than 10x discharge time to 90% usable capacity at nominal line voltage after full load discharge
Communications
- User Interface: LCD Display with blue backlight
- LEDs: (4) LEDs for notice and alarm
- Audible Alarms: Yes
- Communication Ports: (1) RS-232, (1) relay contact, (1) REPO, (2) environmental input
- Communication Slot: (2) X-Slot communication bays
- Power Management Software: Bundled Software Suite CD
Environmental & Standards
- Audible Noise: <53dBA at 1 meter (noise less room) typical
- Operating Temperature: 10°C to +40°C, +45°C with 7.5% derating; Batteries recommended max. +25 C
- Markings: UL, cUL, CSA, CE and NOM-NYCE
- Storage Temperature: -15°C to +25°C
- Relative Humidity: 0-95%, non condensing
Recent News
Spring Facility Check: Don’t Forget Your Lighting Inverter
As winter begins to fade and facilities start their spring maintenance routines, many teams focus on HVAC systems, generators, and electrical inspections. While these...
AI Is Changing Power Demands: Is Your UPS Infrastructure Ready?
{"height":13,"color":{"hue":213,"brightness":0.83,"saturation":1,"alpha":0},"hidden":false,"locked":false,"blockName":"Spacer"} Artificial intelligence isn’t just impacting hyperscale data centers. It’s changing power infrastructure requirements across mid-sized data centers, healthcare facilities, manufacturing plants, and enterprise IT...
The Real Difference Between Entry-Level, Mid-Range, and Enterprise UPS Systems
Choosing the right Uninterruptible Power Supply (UPS) isn’t just about size or price, it’s about matching the right level of protection to your...