| General |
| Topology |
Double-conversion |
| Catalog Number |
K41212000000000 |
| Part Number |
K41212000000000 |
| Color |
Black |
| Rating (VA/Watts) |
12000/10800 |
| |
|
| Diagnostics |
Full system self-test at startup |
| UPS Bypass |
Automatic on overload or UPS failure |
| Dimensions (H x W x D, inches) |
47.8 x 12 x 33.7 |
| Weight (lbs) |
590 |
| Warranty |
Two-year factory warranty |
Contents (Ships with the following items) |
1 ready-to-go UPS Software Suite CD User Guide |
| Efficiency |
92% with nominal linear load; 91% with nominal computer load. |
| |
| Electrical Input |
| Connection |
Hardwired - see manual for terminal block layout
|
| Frequency |
50/60 Hz (45 to 65 Hz) |
| Frequency Range |
45 to 65 Hz |
| Input Power Factor |
P.F >0.99 typical, >0.96 frequency converter |
| Generator Compatability |
Yes |
| |
| Electrical Output |
|
100/200, 110/220, 120/240 Vac 180° phase displacement; 120/208, 127/220 Vac 120° phase displacement |
| Output Receptacles |
(1) PDM
|
| On Utility Voltage Regulation |
Output voltage regulation ±1% Static; ±5% dynamic at 100% resistive load change |
| On Battery Voltage Regulation |
Output voltage regulation ±1% Static; ±5% dynamic at 100% resistive load change |
| Overload Capacity |
150% for 5 sec / 125% for 1 min (online), 110% for 10 min |
| Voltage Wave Shape (On Battery) |
Sine Wave |
| Transfer Time |
0 ms |
| |
| Battery |
| |
 |
| Battery Management |
ABM technology |
| Battery Type |
9Ah, sealed, lead-acid, maintenance-free |
| Battery Replacement |
Field-replaceable |
| Start On Battery |
Allows start of UPS without utility input |
| Recharge Time |
Internal battery: approximately 3 hours to 80% usable capacity at nominal line voltage after full load discharge External battery: no more than 10x discharge time to 90% usable capacity at nominal line voltage after full load discharge |
| |
| Communications |
| User Interface |
LCD Display with blue backlight |
| LEDs |
(4) LEDs for notice and alarm |
| Audible Alarms |
Yes |
| Communication Ports |
(1) RS-232, (1) relay contact, (1) REPO, (2) environmental input |
| Communication Slot |
(2) X-Slot communication bays |
| Power Management Software |
Bundled Software Suite CD |
| |
| Environmental & Standards |
| Audible Noise |
<53dBA at 1 meter (noise less room) typical |
| Operating Temperature |
10°C to +40°C, +45°C with 7.5% derating; Batteries recommended max. +25�C |
| Markings |
UL, cUL, CSA, CE and NOM-NYCE |
| Storage Temperature |
-15°C to +25°C |
| Relative Humidity |
0-95%, non condensing |