Myers Illuminator E-H OSHPD (HID/Motor Loads) Single Phase Lighting Inverter
Myers EPS Illuminator E-H is an OSHPD-rated fast transfer central inverter system for HID and motor loads. The system features a single-cabinet design for units up to 16.7kVA/kW, reducing footprint and installation costs. With a wealth of advanced communications features, the Illuminator E-H offers unmatched convenience.
Capacity and Dimensions
1.5kVA/kW — 5.0kVA/kW: 47″ H x 37″ W x 25″ D
6.0VA/kW — 16.7kVA/kW: 76″ H x 55″ W x 25″ D
Standard Features
Single Phase, Pure Sine Wave
PWM/IGBT Technology
Micro-Processor Control
User Programmable with Password Protection
UL 924 Listed
Automatic Event, Test and Alarm Log
RS232 Communications Port
Input Circuit Breaker
2ms Transfer Time
Low Audible Noise
Space-Saving, Single Cabinet Design
65kAIC Withstand Rating
Warranty:
Electronics – 1 Year Standard Includes All Parts
Batteries – 1 Year Full, 9 Years Prorated
Optional Features
Enhanced Communications
Expanded Building Management Protocols
BACnet or Modbus Communications Interface
NEW IoT Connect Cloud Software
Internal Maintenance Bypass
Summary Alarm Dry Form C Contacts
Status Monitoring Dry Form C Contacts
Remote Meter Panel
Output Circuit Breakers
Factory Startup and Training
Normally Off Output
Output Trip Alarms
Remote Summary and Remote Status Alarm Panels
Onsite Services & Extended Warranty
Specifications:
Input 120 or 277VAC 1 Phase 2 Wire Plus Ground
Output 120 or 277VAC 1 Phase 2 Wire Plus Ground
Output Load Power Factor .5 Lag to.5 Lead
Compatible with all LED Drivers
Forced Air Cooling Only During Emergency Operation; No Air Filters Required
Output Distortion Less than 3% THD for Linear Loads
Generator Compatibility
Custom & Mixed Voltages Available
90 Minute Runtime Standard;
Extended Runtimes Available upon Request
Load Reduction Fault
Meets NFPA-101 for Self-Testing and Self-Diagnostics
Sizes
1.5kVA, 2.25kVA, 3.0kVA, 3.75kVA, 5.0kVA, 6.0kVA, 8.0kVA, 10.0kVA, 12.5kVA & 16.7kVA
Recent News
Spring Facility Check: Don’t Forget Your Lighting Inverter
As winter begins to fade and facilities start their spring maintenance routines, many teams focus on HVAC systems, generators, and electrical inspections. While these...
AI Is Changing Power Demands: Is Your UPS Infrastructure Ready?
{"height":13,"color":{"hue":213,"brightness":0.83,"saturation":1,"alpha":0},"hidden":false,"locked":false,"blockName":"Spacer"} Artificial intelligence isn’t just impacting hyperscale data centers. It’s changing power infrastructure requirements across mid-sized data centers, healthcare facilities, manufacturing plants, and enterprise IT...
The Real Difference Between Entry-Level, Mid-Range, and Enterprise UPS Systems
Choosing the right Uninterruptible Power Supply (UPS) isn’t just about size or price, it’s about matching the right level of protection to your...