Myers Illuminator E (HID/Motor Loads) 1.5kVA-16.7kVA Single Phase Lighting Inverter
Myers EPS Illuminator E is a fast transfer central inverter system for HID and motor loads. The system features a single-cabinet design for units up to 16.7kVA/kW, reducing footprint and installation costs. With a wealth of advanced communications features, the Illuminator E offers unmatched convenience.
Standard Features:
- 98% Efficient Typical
- Automatic Event, Test, and Alarm Log
- User Programmable With Password Protection
- Input Circuit Breaker
- RS232 Communications Port
- Space-Saving Design
- No Break 2ms Transfer Time
- NFPA 101 Self Testing and Data Logging
- Code Compliant: 90 Min. Runtime
- 65 KAIC Input Rating • NEMA Type 1 Cabinet
Optional Features
- Enhanced Communications
-Expanded Building Management Protocols
-BACnet or Modbus Communications Interface
-NEW IoT Connect Cloud Software - Internal or External Maintenance Bypass
- Summary Alarm
- Output Circuit Breakers
- Status Monitoring & Summary Form C Contacts
- Normally Off Output with Time Delay
- Output Trip Alarms
- Seismic
- Factory Startup & Training
- Extended Maintenance & Factory Warranty
Specifications
- Input Voltage: 120 or 277VAC | 1-Phase 2-Wire Plus Ground
- Output Voltage: 120 or 277VAC | 1-Phase 2-Wire Plus Ground
- Output Load Power Factor .5 Lag to .5 Lead
- Output Voltage Distortion Less Than 3% THD for Linear Loads
- Custom Voltage Available (Contact Factory)
- Forced Air Cooling Only During Emergency Operation; No Filters Required
- Compatible with All Lighting and Motor Loads
- Generator Compatibility
- 90 Minute Runtime Standard; Extended Runtimes Available upon Request
Sizes
1.5kVA, 2.25kVA, 3.0kVA, 3.75kVA, 5.0kVA, 6.0kVA, 8.0kVA, 10.0kVA, 12.5kVA & 16.7kVA
Recent News
Spring Facility Check: Don’t Forget Your Lighting Inverter
As winter begins to fade and facilities start their spring maintenance routines, many teams focus on HVAC systems, generators, and electrical inspections. While these...
AI Is Changing Power Demands: Is Your UPS Infrastructure Ready?
{"height":13,"color":{"hue":213,"brightness":0.83,"saturation":1,"alpha":0},"hidden":false,"locked":false,"blockName":"Spacer"} Artificial intelligence isn’t just impacting hyperscale data centers. It’s changing power infrastructure requirements across mid-sized data centers, healthcare facilities, manufacturing plants, and enterprise IT...
The Real Difference Between Entry-Level, Mid-Range, and Enterprise UPS Systems
Choosing the right Uninterruptible Power Supply (UPS) isn’t just about size or price, it’s about matching the right level of protection to your...