Myers Illuminator E (HID/Motor Loads) 1.5kVA-16.7kVA Single Phase Lighting Inverter

$0.00
Adding to Cart Added to Cart

Myers EPS Illuminator E is a fast transfer central inverter system for HID and motor loads. The system features a single-cabinet design for units up to 16.7kVA/kW, reducing footprint and installation costs. With a wealth of advanced communications features, the Illuminator E offers unmatched convenience.

 

Standard Features:

  • 98% Efficient Typical
  • Automatic Event, Test, and Alarm Log
  • User Programmable With Password Protection
  • Input Circuit Breaker
  • RS232 Communications Port
  • Space-Saving Design
  • No Break 2ms Transfer Time
  • NFPA 101 Self Testing and Data Logging
  • Code Compliant: 90 Min. Runtime
  • 65 KAIC Input Rating • NEMA Type 1 Cabinet

 

Optional Features

  • Enhanced Communications
            -Expanded Building Management Protocols
            -BACnet or Modbus Communications Interface
            -NEW IoT Connect Cloud Software
  • Internal or External Maintenance Bypass
  • Summary Alarm
  • Output Circuit Breakers
  • Status Monitoring & Summary Form C Contacts
  • Normally Off Output with Time Delay
  • Output Trip Alarms
  • Seismic
  • Factory Startup & Training
  • Extended Maintenance & Factory Warranty

 

Specifications

  • Input Voltage: 120 or 277VAC | 1-Phase 2-Wire Plus Ground
  • Output Voltage: 120 or 277VAC | 1-Phase 2-Wire Plus Ground
  • Output Load Power Factor .5 Lag to .5 Lead
  • Output Voltage Distortion Less Than 3% THD for Linear Loads
  • Custom Voltage Available (Contact Factory)
  • Forced Air Cooling Only During Emergency Operation; No Filters Required
  • Compatible with All Lighting and Motor Loads
  • Generator Compatibility
  • 90 Minute Runtime Standard; Extended Runtimes Available upon Request

Sizes

1.5kVA, 2.25kVA, 3.0kVA, 3.75kVA, 5.0kVA, 6.0kVA, 8.0kVA, 10.0kVA, 12.5kVA & 16.7kVA

Recent News

Single-Phase vs. Three-Phase UPS: What Growing Businesses Get Wrong

Single-Phase vs. Three-Phase UPS: What Growing Businesses Get Wrong

As businesses grow, so do their power demands. What once worked for a small server room or office network can quickly become inadequate as more...

Read more
How Heat Affects Data Centers and Why Your UPS System Is at Risk

How Heat Affects Data Centers and Why Your UPS System Is at Risk

As temperatures rise and computing demands continue to grow, heat has become one of the most serious threats facing modern data centers, server rooms, and...

Read more
Spring Facility Check: Don’t Forget Your Lighting Inverter

Spring Facility Check: Don’t Forget Your Lighting Inverter

  As winter begins to fade and facilities start their spring maintenance routines, many teams focus on HVAC systems, generators, and electrical inspections. While these...

Read more