Myers Illuminator Hypernova Three Phase Lighting Inverter
Myers EPS’ new Illuminator Hypernova inverters are our sleekest and smartest three-phase units yet! The equipment has been designed with industry leading compact footprint and features many robust communication options, such as the new IoT Inverter Connect cloud connectivity solution. Additionally, the modular battery cabinet configurations optimize mechanical space requirements. These highly efficient systems range from 5.0KVA to 60.0KVA and are perfect for all commercial applications, including schools, data centers, and distribution centers.
Capacity and Dimensions
5.0kVA/kW — 10kVA/kW:
Electronics Cabinet – 47″ H x 24″ W x 25″ D
Battery Cabinet – 62″ H x 17.5″ W x 25″ D
12.5kVA/kW — 16.7kVA/kW:
Electronics Cabinet – 47″ H x 30″ W x 25″ D;
Battery Cabinet – 77″ H x 22.75″ W x 25″ D
25kVA/kW— 33.2kVA/kW:
Electronics Cabinet – 72″ H x 37.5″ W x 25″ D;
Battery Cabinet – 77″ H x 45.5″ W x 25″ D
37.5kVA/kW — 50kVA/kW:
Electronics Cabinet – 72″ H x 37.5″ W x 25″ D;
Battery Cabinet – 77″ H x 68.25″ W x 25″ D
60kVA/kW:
Electronics Cabinet – 72″ H x 44″ W x 31″ D;
Battery Cabinet – 77″ H x 91″ W x 25″ D
Standard Features
98% Efficient Typical
PWM/IGBT Technology and Micro-Controller
Internal Maintenance Bypass
User Programmable with Password Protection
Automatic Event, Test and Alarm Log
RS232 Communications Port
Input Circuit Breaker
2ms Transfer Time
Low Audible Noise (45 dBA @1m)
Space-Saving Design
65kAIC Withstanding Rating
NEMA Type 1 Cabinet
Optional Features
Enhanced Communications
Expanded Building Management Protocols
BACnet or Modbus Communications Interface
New IoT Inverter Connect Cloud Software
External Maintenance Bypass
Summary Alarm Dry Form C Contacts
Internal Output Distribution Circuit Breakers
Factory Startup and Training
Normally Off Output
Output Trip Alarms
Remote Panels (Meter, Status or Summary Alarm)
Extended Factory Warranty and Maintenance Contracts
Specifications:
Input Voltage: 120/208VAC or 277/480 VAC 3-Phase 4-Wire Plus Ground
Output Voltage: 120/208VAC or 277/480 VAC 3-Phase 3 or 4-Wire Plus Ground
Output Load Power Factor .5 Lag to .5 Lead
Compatible with All Lighting and Motor Loads
Forced Air Cooling Only During Emergency Operation; No Filters Required
Output Distortion Less Than 3% THD for Linear Loads
Compatible With Generators (10x Inverter Size)
Custom Voltages Available
90 Minute Runtime Standard; 120 available
Inverter Operating Temperature 32°F to 104°F (0°C to 40°C)
Battery Operating Temperature 68°F to 86°F (20°C to 30°C) per UL 924 Specifications
Sizes
5.0kVA, 7.5kVA, 10.0kVA, 12.5kVA, 16.7kVA, 25.0kVA, 33.2kVA, 37.5kVA, 50.0kVA, & 60.0kVA
Recent News
Lighting Inverters: Ensuring Uninterrupted Safety and Compliance for Emergency Systems
What is a Lighting Inverter? A lighting inverter converts DC battery power to standard AC voltages to provide backup for lighting systems during...
From Power Outages to Business Continuity: How UPS Systems Save the Day
Businesses can't afford unexpected power outages. Even a brief disruption can lead to lost productivity, corrupted data, and decreased customer satisfaction. That's where Uninterruptible...
Power Protection Trends for 2025
As changes in power protection continues to evolve, 2024 has brought significant shifts in the way businesses and organizations approach uninterruptible power supply (UPS) systems...