Myers Illuminator CIII Three Phase Lighting Inverter

$0.00

Only 1 left in stock

Adding to Cart Added to Cart

Myers EPS offers a full line of three phase emergency lighting inverters that provide up to 50kVA/kW of backup power for larger facilities and campuses. The Illuminator CIII is also available as an OSHPD rated unit–contact the factory to learn more.

 

Capacity and Dimensions

4.8kVA/kW — 10kVA/kW: 47″ H x 60″ W x 25″ D
12.5kVA/kW — 16.7kVA/kW: 47″ H x 90″ W x 25″ D
24kVA/kW: 72″ H x 92″ W x 31″ D
33kVA/kW — 50kVA/kW: 72″ H x 140″ W x 31″ D

 

Standard Features


Three Phase, Pure Sine Wave
120V/208V or 277V/480V
UL 924 Self-Testing and Diagnostics via Front Meter Panel
Internal Maintenance Bypass Switch
Front Access, Maintenance-Free VRLA batteries
Supports All Lamp Sources

 

Optional Features


Output Circuit Breakers (10 A — 63 A)
Normally Off Output
20 Year Battery Warranty (1 Year Full; 19 Year Pro-Rated)
Output Trip Alarm
Status Monitoring Contacts
Form C Contacts
Alternate Cabinet Configurations
OSHPD Rated Units (Contact Factory)

 

Specifications:

 

Input 120/208 or 277/480 VAC 3 Phase 4 Wire Wye Configuration
Output 120/208 or 277/480 VAC 3 Phase Wye Or Delta Configuration
Output Load Power Factor .5 Lag to .5 Lead
LED, Electronic & Magnetic Ballast Compatible
Output Distortion Less Than 3% THD For Linear Loads
Forced Air Cooling Only During Emergency Operation; No Filters Required
Generator Compatibility
90 Minute Runtime Standard;
Additional Runtimes Available Upon Request

 

Sizes


4.8kVA, 6kVA, 8kVA, 10kVA, 12.5kVA, 16.7kVA, 24kVA, 33kVA, 40kVA & 50kVA

Recent News

Spring Facility Check: Don’t Forget Your Lighting Inverter

Spring Facility Check: Don’t Forget Your Lighting Inverter

  As winter begins to fade and facilities start their spring maintenance routines, many teams focus on HVAC systems, generators, and electrical inspections. While these...

Read more
AI Is Changing Power Demands: Is Your UPS Infrastructure Ready?

AI Is Changing Power Demands: Is Your UPS Infrastructure Ready?

 {"height":13,"color":{"hue":213,"brightness":0.83,"saturation":1,"alpha":0},"hidden":false,"locked":false,"blockName":"Spacer"} Artificial intelligence isn’t just impacting hyperscale data centers. It’s changing power infrastructure requirements across mid-sized data centers, healthcare facilities, manufacturing plants, and enterprise IT...

Read more
The Real Difference Between Entry-Level, Mid-Range, and Enterprise UPS Systems

The Real Difference Between Entry-Level, Mid-Range, and Enterprise UPS Systems

    Choosing the right Uninterruptible Power Supply (UPS) isn’t just about size or price, it’s about matching the right level of protection to your...

Read more