Myers EPS Illuminator EM central lighting inverter system combines the full features of the Illuminator Series E and the small, compact footprint of the Illuminator CM. The Illuminator EM system is available in 1000VA/W — 2800VA/W capacities. The EM system features the industry’s smallest cabinetry — even when all optional equipment is incorporated — and can be either wall or floor mounted. As with all Myers EPS Lighting Inverter Systems, our fast transfer technology is 98% efficient and can support all lamp sources including HID and LED.

 


Standard Features


98% Efficient Typical
Automatic Event, Test, and Alarm Log
User Programmable With Password Protection
Input Circuit Breaker
One Output Circuit Breaker
RS232 Communications Port
Space-Saving Design
No Break 2ms Transfer Time
NFPA 101 Self Testing and Data Logging
Code Compliant : 90 Min. Runtime
65 KAIC Input Rating • NEMA Type 1 Cabinet

 

Optional Features


Enhanced Communications
Expanded Building Management Protocols
BACnet or Modbus Communications Interface
NEW IoT Connect Cloud Software
Internal or External Maintenance Bypass
Summary Alarm
Output Circuit Breakers
Status Monitoring & Summary Form C Contacts
Normally Off Output With Variable Time Delay
Output Trip Alarms
Wall Bracket, Floor Bracket, or Seismic
Factory Startup & Training
Extended Maintenance & Factory Warranty

 

Specifications


Input Voltage: 120 or 277VAC | 1-Phase 2-Wire Plus Ground
Output Voltage: 120 or 277VAC | 1-Phase 2-Wire Plus Ground
Output Load Power Factor .5 Lag to .5 Lead
Output Voltage Distortion Less Than 3% THD for Linear Loads
Forced Air Cooling Only During Emergency Operation; No Filters Required
Compatible with All Lighting and Motor Loads
Compatible With Generators (10x Inverter Size)
Custom Voltage Available (Contact Factory)

 

Sizes


1.0kVA, 1.6kVA, 2.2kVA & 2.8kVA

Recent News

Spring Facility Check: Don’t Forget Your Lighting Inverter

Spring Facility Check: Don’t Forget Your Lighting Inverter

  As winter begins to fade and facilities start their spring maintenance routines, many teams focus on HVAC systems, generators, and electrical inspections. While these...

Read more
AI Is Changing Power Demands: Is Your UPS Infrastructure Ready?

AI Is Changing Power Demands: Is Your UPS Infrastructure Ready?

 {"height":13,"color":{"hue":213,"brightness":0.83,"saturation":1,"alpha":0},"hidden":false,"locked":false,"blockName":"Spacer"} Artificial intelligence isn’t just impacting hyperscale data centers. It’s changing power infrastructure requirements across mid-sized data centers, healthcare facilities, manufacturing plants, and enterprise IT...

Read more
The Real Difference Between Entry-Level, Mid-Range, and Enterprise UPS Systems

The Real Difference Between Entry-Level, Mid-Range, and Enterprise UPS Systems

    Choosing the right Uninterruptible Power Supply (UPS) isn’t just about size or price, it’s about matching the right level of protection to your...

Read more