Myers Illuminator IE-H OSHPD (LED & Non-HID Loads) Single Phase Lighting Inverter

$0.00 Sale Save

Item is in stock Only 0 left in stock Item is out of stock Item is unavailable

Adding to Cart Added to Cart

Myers EPS Illuminator E-H is an OSHPD-rated fast transfer central inverter system for all lighting & motor loads. The system features a single-cabinet design for units up to 16.7kVA/kW, reducing footprint and installation costs. With a wealth of advanced communications features, the Illuminator E-H offers unmatched convenience.

 

Capacity and Dimensions


1.5kVA/kW — 5.0kVA/kW: 47″ H x 37″ W x 25″ D
6.0VA/kW — 16.7kVA/kW: 76″ H x 55″ W x 25″ D

 

Standard Features


Single Phase, Pure Sine Wave
Compatible with LED, HID, and Motor Loads
PWM/IGBT Technology
Micro-Processor Control
User Programmable with Password Protection
UL 924 Listed
Automatic Event, Test and Alarm Log
RS232 Communications Port
Input Circuit Breaker
2ms Transfer Time
Low Audible Noise
Space-Saving, Single Cabinet Design
65kAIC Withstand Rating
Warranty:
Electronics – 1 Year Standard Includes All Parts
Batteries – 1 Year Full, 9 Years Prorated

 

Optional Features


Enhanced Communications
Expanded Building Management Protocols
BACnet or Modbus Communications Interface
NEW IoT Connect Cloud Software
Internal Maintenance Bypass
Summary Alarm Dry Form C Contacts
Status Monitoring Dry Form C Contacts
Remote Meter Panel
Output Circuit Breakers
Factory Startup and Training
Normally Off Output
Output Trip Alarms
Remote Summary and Remote Status Alarm Panels
Onsite Services & Extended Warranty

 

Specifications:

 

Input 120 or 277VAC 1 Phase 2 Wire Plus Ground
Output 120 or 277VAC 1 Phase 2 Wire Plus Ground
Output Load Power Factor .5 Lag to.5 Lead
Compatible with all LED Drivers
Forced Air Cooling Only During Emergency Operation; No Air Filters Required
Output Distortion Less than 3% THD for Linear Loads
Compatible with Generators (10x Inverter Size)
Custom Voltages Available
90 Minute Runtime Standard; Other Runtimes Available upon Request
Load Reduction Fault
Meets NFPA-101 for Self-Testing and Self-Diagnostics

 

Sizes


1.5kVA, 2.25kVA, 3.0kVA, 3.75kVA, 5.0kVA, 6.0kVA, 8.0kVA, 10.0kVA, 12.5kVA & 16.7kVA

Recent News

How Education Systems Rely on UPS Systems

How Education Systems Rely on UPS Systems

As students return to classrooms this fall, schools, colleges, and universities face increasing demands on their technology and power infrastructure. From digital learning platforms to...

Read more
Why Modular UPS Systems Are a Smart Power Strategy

Why Modular UPS Systems Are a Smart Power Strategy

  Today’s IT environments are evolving fast. From growing server rooms to decentralized facilities, one thing remains constant—reliable, scalable power protection is essential. Traditional UPS...

Read more
How to Choose the Right UPS System for Your Business: A No-Nonsense Buyer’s Guide

How to Choose the Right UPS System for Your Business: A No-Nonsense Buyer’s Guide

Downtime is expensive. Whether you're running a data center, a healthcare facility, or a manufacturing line, power interruptions can disrupt operations and lead to major...

Read more