Toshiba 1600XP 6kVA / 5.1KW 208/240V Online Tower UPS (Pre-owned)
*Preowned* The 1600XP/XPi Series is single-phase double-conversion UPS, available in a range of sizes: 3.6 kVA, 6.0 kVA, 8.0 kVA, 10.0 kVA, 14 kVA, 18 kVA, and 22 kVA. As a double-conversion online UPS, supplies uninterrupted, clean single-phase power to critical systems over large input voltage deviations without resorting to battery backup.
The 1600XP Single phase UPS is an on-line double conversion tower design UPS ranging in capacity from 3.6 to 22 kVA. Toshiba uninterruptible power supply is designed to meet the growing demand in the information technology, healthcare, industrial, broadcasting and retail markets. The 1600XP UPS ensures clean power, no power interruption in the event of a power outage. Toshiba UPS solutions offer emergency backup power to protect vital electronic resources from today’s all-too often blackouts, brownouts and power surges.
Key Features:
- Hot Swappable Batteries
- Internal Isolation Transformer
- Wide Input Voltage Window
- Wide Input Frequency Window
- Input Power Factor; 0.95
- Power Factor Correction
- Output Power Factor 0.85
Specifications:
- Model Number: UH3G2L060C61T
- Capacity (kVA/kW) : 6.0/5.1KW
- Topology : True On-Line, Double-Conversion
- Standard Voltage: 208/240V/120V
- Phase: 1PH
- Frequency: 50/60HZ
- DC Voltage: 216V
- Voltage THD : < 3% for linear load; < 6% for non-linear load
- Overload Capacity : Inverter: 125%-30 sec./150%-10 sec, Bypass: 125%-10 min./1000%-1 cycle
- Temperature Range: 32° to 104°F (0° to 40°C)
- Humidity : 30% to 90% Non-Condensing
- Heat Rejection : 3564 BTU/Hr
- Full-Load Efficiency : 0.83
- Altitude : 6600 ft. (2000 m) Maximum Without Derating
- Audible Noise : 60dBA @ 1 m Typical
- Dimensions : 10" x 34" x 27.5"
- Weight: 354lbs.
- Features : Output Isolation Transformer, RS232 & Dry Contact Interface, Crest Factor of 3, Angled Terminal Blocks for Easy Installation, Casters for Mobility
- Standards : UL 1778, CUL
Notes:
System may show minor signs of wear consistent with previous installation.
New internal batteries included.
Modified 240V output plug.
Wiring and startup of system by trained/certified professional required.
Recent News
Single-Phase vs. Three-Phase UPS: What Growing Businesses Get Wrong
As businesses grow, so do their power demands. What once worked for a small server room or office network can quickly become inadequate as more...
How Heat Affects Data Centers and Why Your UPS System Is at Risk
As temperatures rise and computing demands continue to grow, heat has become one of the most serious threats facing modern data centers, server rooms, and...
Spring Facility Check: Don’t Forget Your Lighting Inverter
As winter begins to fade and facilities start their spring maintenance routines, many teams focus on HVAC systems, generators, and electrical inspections. While these...