NOTE:  Serial number of unit may be different than seen in photos due to multiple units being available.

 

Output:

Output power capacity

4.2kW / 6.0kVA

Max Configurable Power (Watts)

4.2kW / 6.0kVA

Nominal Output Voltage

208V

Output Voltage Note

Configurable for 208 or 240 nominal output voltage

Efficiency at Full Load

92.0 %

Output Voltage Distortion

Less than 3%

Output Frequency (sync to mains)

50/60 Hz +/- 3 Hz user adjustable +/- 0.1

Other Output Voltages

240

Load Crest Factor

3:1

Topology

Double Conversion Online

Waveform type

Sine wave

Output Connections

(2) NEMA L6-20R (Battery Backup)

(2) NEMA L6-30R (Battery Backup)

Bypass

Internal Bypass (Automatic and Manual)


Input:

Nominal Input Voltage

208V

Input frequency

50/60 Hz +/- 5 Hz (auto sensing)

Input Connections

NEMA L6-30P

Cord Length

10ft (3.05meters)

Input voltage range for main operations

160 - 280V

Input voltage adjustable range for mains operation

100 - 280V

Number of Power Cords

1

Efficiency at Full Load

92.0 %

Other Input Voltages

240


Physical:

Maximum Height

5.1 inches (130mm, 13.0cm)

Maximum Width

17.0 inches (432mm, 43.2cm)

Maximum Depth

26.0 inches (660mm, 66.0cm)

Rack Height

3U

Net Weight

120.0 lbs.

Recent News

Single-Phase vs. Three-Phase UPS: What Growing Businesses Get Wrong

Single-Phase vs. Three-Phase UPS: What Growing Businesses Get Wrong

As businesses grow, so do their power demands. What once worked for a small server room or office network can quickly become inadequate as more...

Read more
How Heat Affects Data Centers and Why Your UPS System Is at Risk

How Heat Affects Data Centers and Why Your UPS System Is at Risk

As temperatures rise and computing demands continue to grow, heat has become one of the most serious threats facing modern data centers, server rooms, and...

Read more
Spring Facility Check: Don’t Forget Your Lighting Inverter

Spring Facility Check: Don’t Forget Your Lighting Inverter

  As winter begins to fade and facilities start their spring maintenance routines, many teams focus on HVAC systems, generators, and electrical inspections. While these...

Read more