Liebert GXT2-1500RT120 1500VA / 1050W 120V Online 2U Rack/Tower UPS
$299.99
Liebert GXT2-1500RT120 1500VA / 1050W 120V Online 2U Rack/Tower UPS- New Battery
Professionally re-certified with new batteries installed. May show minor signs of wear consistent with previous installation.
GXT2-1500RT120 Specifications:
| Power Rating | |
| Rating, VA | 1500VA |
| Rating, W | 1050W |
Input AC Specifications |
|
| Phase | 1 |
| Power Factor | 0.97 |
| Input Frequency, Hz | 50/60 |
| Frequency Range, Hz | 40 - 70 Hz; Auto Sensing |
| Input Voltage Range, VAC | 60 - 140 |
| Input Voltage | 100/110/115/120/127 |
| Input Connections or Input Cord/Plug Type | (10 ft) NEMA 5-15P |
General Specifications |
|
| UPS Technology | On-Line |
Battery Specifications |
|
| Battery Test Type | Manual & Automatic |
| Runtime, Full Load, Watt | 7 min. |
| Runtime, Half Load, Watt | 20 min. |
| Recharge Time | 5 Hrs to 95% |
| User Replaceable Battery | Yes |
| Battery Technology | VRLA |
| Output Waveform on Battery | Sinewave |
Output AC Specifications |
|
| Nominal Voltage | 100/110/115/120/127V +/- 3% |
| Output Waveform | Sinewave |
| Receptacles (b=Battery, s=Surge) | (6) NEMA 5-15R |
User Interface |
|
| Audible Alarms | Yes |
| Display Type | LED |
Communications |
|
| Communications Options | SNMP/RS232 |
| Software and Cable | N/A |
| Software and Cable | Multilink SW & Serial Cable |
Physical Data |
|
| Color | Black |
| Form Factor | Racktower |
| Unit Height, inches (mm) | 17.0 (430) |
| Unit Width, inches (mm) | 3.5 (87) |
| Unit Depth, inches (mm) | 21.5 (547) |
| Unit Weight, lbs. (kg) | 50.6 (23.0) |
| Shipping Height, inches (mm) | 23.0 (584) |
| Shipping Width, inches (mm) | 10.6 (269) |
| Shipping Depth, inches (mm) | 27.2 (691) |
| Shipping Weight, lbs. (kg) | 59.5 (27.0) |
Environmental |
|
| Operating Temperature, Minimum °F (°C) | 32 (0) |
| Operating Temperature, Maximum °F (°C) | 104 (40) |
| Storage Temperature, Minimum °F (°C) | 5 (-15 ) |
| Storage Temperature, Maximum °F (°C) | 104 (40) |
| Relative Humidity | 0% to 95%, Non Condensing |
| Operating Elevation, ft. (m) | Up to 10,000 (3000) |
| Sound Emission/Audible Noise | < 50dBA, at 1 meter |
| Cooling | Fan Cooled |
Options |
|
| Optional Items | External Battery Cabinets |
| Agency/Certification/Conformance | |
| Agency Approval | cUL Listed, FCC Part 15, Subpart B, Class A, UL 1778, UL Listed |
Recent News
Single-Phase vs. Three-Phase UPS: What Growing Businesses Get Wrong
As businesses grow, so do their power demands. What once worked for a small server room or office network can quickly become inadequate as more...
How Heat Affects Data Centers and Why Your UPS System Is at Risk
As temperatures rise and computing demands continue to grow, heat has become one of the most serious threats facing modern data centers, server rooms, and...
Spring Facility Check: Don’t Forget Your Lighting Inverter
As winter begins to fade and facilities start their spring maintenance routines, many teams focus on HVAC systems, generators, and electrical inspections. While these...