![Eaton 5P 5P1000RC 1000VA/770W 120V 2U Compact Line-interactive Rackmount UPS](http://cpwarehouse.com/cdn/shop/products/5P750RC_C_1000x1000_300dpi_2896049c-3577-428b-a6b4-e09a7c828096_200x200_crop_center.jpg?v=1580753078)
![Eaton 5P 5P1000RC 1000VA/770W 120V 2U Compact Line-interactive Rackmount UPS](http://cpwarehouse.com/cdn/shop/products/5P750RC_R_1000x1000_300dpi_a8e485b9-521b-4299-bf8d-bbbbec98ef5a_200x200_crop_center.jpg?v=1580753078)
![Eaton 5P 5P1000RC 1000VA/770W 120V 2U Compact Line-interactive Rackmount UPS](http://cpwarehouse.com/cdn/shop/products/5PCOMPACT_BK_1000x1000_300dpi_702f0b7a-6243-4acb-bceb-c7acbaf595f9_200x200_crop_center.jpg?v=1580753078)
![Eaton 5P 5P1000RC 1000VA/770W 120V 2U Compact Line-interactive Rackmount UPS](http://cpwarehouse.com/cdn/shop/products/5PCOMPARISON_C_1000x1000_300dpi_b229a5b9-f840-4182-a197-a7a0169083b6_200x200_crop_center.jpg?v=1580753078)
Eaton 5P 5P1000RC 1000VA/770W 120V 2U Compact Line-interactive Rackmount UPS
$640.99
Eaton 5P 5P1000RC 1000VA/770W 120V 2U Compact Line-interactive Rackmount UPS
General | |
Topology | Line interactive |
Configuration | Rackmount / Wallmount |
Color | Black and silver |
Rating (VA/Watts) | 1000/770 |
Diagnostics | Full system self-test at power up |
Dimensions (H x W x D, inches) | 3.4 (2U) x 17.3 x 16.0 |
Dimensions (H x W x D, mm) | 86.2 x 440 x 405 |
Weight (kg) | 15 |
Weight (lbs) | 33 |
Warranty | 3 years on electronics, 3 years on batteries with registration |
Rail Kit Included | Two-post rail kit, four-post rail kit, wall-mount kit |
Remote Emergency Power off (REPO) | ROO/RPO: Rear terminal block connector for remote on/off and power off |
Contents (Ships with the following items) |
5P rackmount compact UPS Quick start guide USB cable RS-232 serial cable Multi-purpose rail kit |
Efficiency | up to 95.9% |
Electrical Input | |
Connection |
(1) NEMA 5-15P
|
Input Cord | 6 feet (1.8 meters) |
Input Voltage Range | 89–151 Vac (adjustable to 70–153 Vac) |
Nominal Voltage | 120 Vac (adjustable to100/120/125 Vac) |
Frequency | 50/60 Hz (auto-sensing) |
Frequency Range | 47–70 Hz (50 Hz system), 56.5–70 Hz (60 Hz system), 40-70 Hz in low-sensitivity mode |
Electrical Output | |
Nominal Voltage | 120V default (100/120/125V) |
Output Receptacles |
(10) NEMA 5-15R
|
On Utility Voltage Regulation | 102–132 Vac |
On Battery Voltage Regulation | -10%, +6% of nominal |
Output Frequency | 50/60 Hz ±0.1 % (autosensing) |
Load Segments | Group 1: (3) 5-15R outlets; Group 2: (3) 5-15R outlets view load segments application note |
Communications | |
User Interface | LCD graphical display |
LEDs | Load protected, on battery and fault |
Communication Ports | RS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included |
Communications Card Slots | One slot; Network Card-MS is optional |
Power Management Software | Eaton Intelligent Power Manager (included) |
Environmental & Standards | |
RoHS Compliance | Yes |
Heat Dissipation (BTU) | Line: 106, Battery 500 |
Audible Noise | <45 dB at 1 meter |
Operating Temperature | 0 to 35°C (32°F to 95°F) |
Performance - Safety - EMC | UL 1778, UL497A |
Safety markings | cULus, CE |
EMC Markings | IEC 62040-2 C1-C2 / EN 55024 / CISPR22 Class B / FCC part 15 Class B |
Storage Temperature | -15°C – 40°C (5°F – 104°F) |
Relative Humidity | 0–90% non-condensing |
Altitude | Up to 10,000 ft (3000m) without de-rating |