General
Topology Line interactive
Configuration Rackmount / Wallmount
Color Black
Rating (VA/Watts) 1500/1100
 
Diagnostics Full system self-test at power up
Dimensions (H x W x D, inches) 1.7 (1U) x 17.2 x 21.8
Dimensions (H x W x D, mm) 43.2 x 438 x 554
Weight (kg) 16.5
Weight (lbs) 36.4
Warranty 5 years on electronics, 5 years on batteries with registration
 
Electrical Input
Connection
(1) NEMA 5-15P

Input Voltage Range 89–151 Vac (adjustable to 70–153 Vac)
Nominal Voltage 120 Vac (adjustable to100/120/125 Vac)
Frequency 50/60 Hz (auto-sensing)
Frequency Range 47–70 Hz (50 Hz system), 56.5–70 Hz (60 Hz system), 40-70 Hz in low-sensitivity mode
 
Electrical Output
Nominal Voltage 120V default (100/120/125V)
Output Receptacles
(6) NEMA 5-15R

On Utility Voltage Regulation 102–132 Vac
On Battery Voltage Regulation -10%, +6% of nominal
Output Frequency 50/60 Hz ±0.1 % (autosensing)
Load Segments Group 1: (2) 5-15R outlets; Group 2: (1) 5-15R outlet, Main: (3) outlets
view load segments application note
Battery Description Lithium-ion battery pack
Battery Management Integrated Battery Management System (BMS) for life cycle monitoring
Battery Type Lithium Iron Phosphate (LFP) battery chemistry
Battery Replacement User replaceable internal batteries
Extended Battery Capability None; See Eaton 5PX UPS for extended runtimes
Start On Battery Allows start of UPS without utility power (First time start must be on AC power)
 
Communications
User Interface LCD graphical display
LEDs Load protected, on battery and fault
Communication Ports RS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included
Communications Card Slots One slot; Network Card-MS is optional
Power Management Software Eaton Intelligent Power Software Suite
 
Environmental & Standards
RoHS Compliance Yes
Audible Noise <45 dB at 1 meter
Operating Temperature 5 to 40°C (41°F to 104°F)
Performance - Safety - EMC UL1778, cULus, UN38.3, UL1973, IEC 62619, NOM
Safety markings cULus, CE
EMC Markings IEC 62040-2 C1-C2 / FCC part 15 Class B
Storage Temperature -15°C–50°C (5°F–122°F)
Relative Humidity 0–90% non-condensing
Altitude Up to 10,000 ft (3000m) without de-rating


Recent News

Single-Phase vs. Three-Phase UPS: What Growing Businesses Get Wrong

Single-Phase vs. Three-Phase UPS: What Growing Businesses Get Wrong

As businesses grow, so do their power demands. What once worked for a small server room or office network can quickly become inadequate as more...

Read more
How Heat Affects Data Centers and Why Your UPS System Is at Risk

How Heat Affects Data Centers and Why Your UPS System Is at Risk

As temperatures rise and computing demands continue to grow, heat has become one of the most serious threats facing modern data centers, server rooms, and...

Read more
Spring Facility Check: Don’t Forget Your Lighting Inverter

Spring Facility Check: Don’t Forget Your Lighting Inverter

  As winter begins to fade and facilities start their spring maintenance routines, many teams focus on HVAC systems, generators, and electrical inspections. While these...

Read more