Eaton 5P 5P1550GR-L 1550VA/1100W 208-240V 1U Lithium Ion Rackmount UPS
$2,469.90
Eaton 5P 5P1550GR-L 1550VA/1100W 208-240V 1U Lithium Ion Rackmount UPS
General | |
Topology | Line interactive |
Configuration | Rackmount / Wallmount |
Color | Blue and black |
Rating (VA/Watts) | 1550/1100 |
Diagnostics | Full system self-test at power up |
Dimensions (H x W x D, inches) | 1.7 (1U) x 17.2 x 21.8 |
Dimensions (H x W x D, mm) | 43.2 x 438 x 554 |
Weight (kg) | 15.7 |
Weight (lbs) | 34.7 |
Warranty | 5 years on electronics, 5 years on batteries with registration |
Rail Kit Included | 4-post rail kit |
Remote Emergency Power off (REPO) | ROO/RPO: Rear terminal block connector for remote on/off and power off |
Contents (Ships with the following items) |
5P UPS Quick start guide USB cable RS-232 serial cable 4-post rail kit 2 IEC-to-IEC jumper cables Output cable locking system Input cable locking system |
Efficiency | up to 98% |
Electrical Input | |
Connection |
(1) IEC-320-C14
|
Input Voltage Range | 160-294Vac (adjustable to 150-294 Vac) |
Nominal Voltage | 230Vac (adjustable to 200/208/220/230/240 Vac) |
Frequency | 50/60 Hz (auto-sensing) |
Frequency Range | 47–70 Hz (50 Hz system), 56.5–70 Hz (60 Hz system), 40-70 Hz in low-sensitivity mode |
Electrical Output | |
Nominal Voltage | 230V default (200/208/220/230/240V) |
Output Receptacles |
(6) IEC-320-C13
|
On Utility Voltage Regulation | 184-256 Vac |
On Battery Voltage Regulation | -10%, +6% of nominal |
Output Frequency | 50/60 Hz ±0.1 % (autosensing) |
Load Segments | Group 1: (2) C13 outlets; Group 2: (1) C13 outlets, Main: (3) C13 outlets view load segments application note |
Communications | |
User Interface | LCD graphical display |
LEDs | Load protected, on battery and fault |
Communication Ports | RS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included |
Communications Card Slots | One slot; Network Card-MS is optional |
Power Management Software | Eaton Intelligent Power Software Suite |
Environmental & Standards | |
RoHS Compliance | Yes |
Heat Dissipation (BTU) | Line: 113, Battery 714 |
Audible Noise | <45 dB at 1 meter |
Operating Temperature | 5 to 40°C (41°F to 104°F) |
Performance - Safety - EMC | UL1778, cULus, UN38.3, UL1973, IEC 62619 |
Safety markings | cTUVus, CE |
EMC Markings | IEC 62040-2 C1-C2 / EN 55024 / CISPR22 Class B / FCC part 15 Class B |
Storage Temperature | -15°C–50°C (5°F–122°F) |
Relative Humidity | 0–90% non-condensing |
Altitude | Up to 10,000 ft (3000m) without de-rating |
Recent News
Lighting Inverters: Ensuring Uninterrupted Safety and Compliance for Emergency Systems
What is a Lighting Inverter? A lighting inverter converts DC battery power to standard AC voltages to provide backup for lighting systems during...
From Power Outages to Business Continuity: How UPS Systems Save the Day
Businesses can't afford unexpected power outages. Even a brief disruption can lead to lost productivity, corrupted data, and decreased customer satisfaction. That's where Uninterruptible...
Power Protection Trends for 2025
As changes in power protection continues to evolve, 2024 has brought significant shifts in the way businesses and organizations approach uninterruptible power supply (UPS) systems...