Eaton 5P 5P3000RT 3000VA/2700W 120V 2U Rack / Tower Line Interactive UPS

$1,947.90

Adding to Cart Added to Cart

Eaton 5P 5P3000RT 3000VA/2700W 120V 2U Rack / Tower Line Interactive UPS

General
Topology Line interactive
Configuration Rack/Tower
Color Black
Rating (VA/Watts) 3000/2700
 
Diagnostics Full system self-test at power up
UPS Bypass EHBPL3000R-PDU1U (optional)
Dimensions (H x W x D, inches) 3.4 x 17.4 x 25.5
Dimensions (H x W x D, mm) 86 x 441 x 647
Weight (kg) 40
Weight (lbs) 87
Warranty 3 years on electronics, 3 years on batteries with registration
Rail Kit Included Tower stands and 4-post rail kit included
Contents
(Ships with the following items)
5P3000RT
Four-post rail kit
User manual CD
Tower pedestals
Intelligent Power Software Suite CD
Quick start guide
RS-232 serial cable
USB cable
Phillips head screw driver
Electrical Input
Connection
(1) NEMA L5-30P

Input Cord 10 ft
Input Voltage Range 89–151 Vac (adjustable to 70–153 Vac)
Nominal Voltage 120 Vac (adjustable to100/120/125 Vac)
Frequency 50/60 Hz (auto-sensing)
Frequency Range 47–70 Hz (50 Hz system), 56.5–70 Hz (60 Hz system), 40 Hz in low-sensitivity mode
Input Power Factor 0.9
 
Electrical Output
Output Receptacles
(6) NEMA 5-20R

(1) NEMA L5-30R

On Utility Voltage Regulation 102–132 Vac
On Battery Voltage Regulation -10%, +6% of nominal
Output Frequency 50/60 Hz ±0.1 % (autosensing)
Load Segments Group 1: (2) 5-20R outlets; Group 2: (2) 5-20R outlets
view load segments application note
Communications
User Interface LCD graphical display
LEDs Load protected, battery and fault
Communication Ports 1 USB HID compliant port + 1 RS232 serial port and relay contacts (USB and RS232 ports cannot be used simultaneously)
Communications Card Slots 1 slot for ConnectUPS-MS network management card
Power Management Software Eaton Intelligent Power Software Suite CD (included)
 
Environmental & Standards
Heat Dissipation (BTU) Line: 305, Battery: 2047
Audible Noise <50 dBA
Operating Temperature 0°C–40°C (32°F–104°F)
Performance - Safety - EMC UL1778; UL497A; cUL
Safety markings UL, cUL
EMC Markings FCC Part 15 subpart B Class A
Storage Temperature -15°C–50°C (5°F–122°F)
Relative Humidity 20–95% non-condensing
Altitude Up to 10,000 ft (3000m) without de-rating

Recent News

Cold Weather UPS Maintenance Tips for Data Centers and IT Infrastructure

Cold Weather UPS Maintenance Tips for Data Centers and IT Infrastructure

As temperatures drop, data centers and IT facilities face new challenges that can impact the performance and reliability of their uninterruptible power supply (UPS) systems....

Read more
Lighting Inverters: Reliable Backup Power for Emergency Lighting

Lighting Inverters: Reliable Backup Power for Emergency Lighting

When power fails, lighting inverters are the unsung heroes that keep pathways illuminated, life safe, and buildings code-compliant. In this post, we’ll explain what lighting...

Read more
How Education Systems Rely on UPS Systems

How Education Systems Rely on UPS Systems

As students return to classrooms this fall, schools, colleges, and universities face increasing demands on their technology and power infrastructure. From digital learning platforms to...

Read more