Eaton 5PX 5PX3000iRT2U 3000VA/2700W 208/230V Rack/Tower Line Interactive UPS
$2,214.99
Eaton 5PX 5PX3000iRT2U 3000VA/2700W 208/230V Rack/Tower Line Interactive UPS
| General | |
| Topology | Line interactive |
| Configuration | Rack/Tower |
| Catalog Number | 5PX3000iRT2U |
| Color | Black |
| Rating (VA/Watts) | 3000/2700 |
| Diagnostics | Full system self-test at power up |
| Dimensions (H x W x D, inches) | 3.4 x 17.4 x 25.5 |
| Dimensions (H x W x D, mm) | 86 x 441 x 647 |
| Weight (kg) | 38 |
| Weight (lbs) | 84 |
| Warranty | 3 years on electronics, 3 years on batteries with registration |
| Rail Kit Included | Tower stands and 4-post rail kit included |
| Contents (Ships with the following items) |
5PX3000iRT2U Four-post rail kit User manual CD Tower pedestals Intelligent Power Software Suite CD Quick start guide RS-232 serial cable USB cable 2 IEC to IEC jumper cables Phillips head screw driver |
| Electrical Input | |
| Connection |
(1) IEC-320-C20
|
| Input Voltage Range | 160–294 Vac (adjustable to 150–294 Vac) |
| Nominal Voltage | 230 Vac (adjustable to 200/208/220/230/240 Vac) |
| Frequency | 50/60 Hz (auto-sensing) |
| Frequency Range | 47–70 Hz (50 Hz system), 56.5–70 Hz (60 Hz system), 40 Hz in low-sensitivity mode |
| Input Power Factor | 0.9 |
| Electrical Output | |
| Output Receptacles |
(8) IEC-320-C13
(1) IEC-320-C19
|
| On Utility Voltage Regulation | 184–265 Vac |
| On Battery Voltage Regulation | -10%, +6% of nominal |
| Output Frequency | 50/60 Hz ±0.1 % (autosensing) |
| Transfer Time | 1–4 ms typical |
| Load Segments | Group 1: (2) C13 outlets Group 2: (2) C13 outlets view load segments application note |
| Communications | |
| User Interface | LCD graphical display |
| LEDs | Load Protected, Battery, and Fault |
| Communication Ports | 1 USB HID compliant port + 1 RS232 serial port and relay contacts (USB and RS232 ports cannot be used simultaneously) |
| Communications Card Slots | 1 slot for ConnectUPS-MS network management card |
| Power Management Software | Eaton Intelligent Power Software Suite CD (included) |
| Environmental & Standards | |
| Heat Dissipation (BTU) | Line: 305, Battery: 2047 |
| Audible Noise | <50 dBA |
| Operating Temperature | 0°C–40°C (32°F–104°F) |
| Performance - Safety - EMC | IEC/EN 62040-1-1 (Safety), IEC/EN 62040-2 (EMC), IEC/EN 62040-3 (Performance) |
| Safety markings | CE, CB report, TÜV |
| Storage Temperature | -15°C–50°C (5°F–122°F) |
| Relative Humidity | 20–95% non-condensing |
| Altitude | Up to 10,000 ft (3000m) without de-rating |
Recent News
Planning IT Infrastructure Growth for the 2026 New Year!
As the calendar flips toward a new year, businesses across every industry start looking ahead - evaluating what worked, what didn’t, and what needs to...
Cold Weather UPS Maintenance Tips for Data Centers and IT Infrastructure
As temperatures drop, data centers and IT facilities face new challenges that can impact the performance and reliability of their uninterruptible power supply (UPS) systems....
Lighting Inverters: Reliable Backup Power for Emergency Lighting
When power fails, lighting inverters are the unsung heroes that keep pathways illuminated, life safe, and buildings code-compliant. In this post, we’ll explain what lighting...