Eaton 5PX 5PX3000RT2U 3000VA/2700W 120V Rack/Tower Line Interactive UPS
$1,885.99
Eaton 5PX 5PX3000RT2U 3000VA/2700W 120V Rack/Tower Line Interactive UPS
General | |
Topology | Line interactive |
Configuration | Rack/Tower |
Catalog Number | 5PX3000RT2U |
Color | Black |
Rating (VA/Watts) | 3000/2700 |
Diagnostics | Full system self-test at power up |
UPS Bypass | EHBPL3000R-PDU1U (optional) |
Dimensions (H x W x D, inches) | 3.4 x 17.4 x 25.5 |
Dimensions (H x W x D, mm) | 86 x 441 x 647 |
Weight (kg) | 40 |
Weight (lbs) | 87 |
Warranty | 3 years on electronics, 3 years on batteries with registration |
Rail Kit Included | Tower stands and 4-post rail kit included |
Contents (Ships with the following items) |
5PX3000RT2U Four-post rail kit User manual CD Tower pedestals Intelligent Power Software Suite CD Quick start guide RS-232 serial cable USB cable Phillips head screw driver |
Electrical Input | |
Connection |
(1) NEMA L5-30P
|
Input Cord | 10 ft |
Input Voltage Range | 89–151 Vac (adjustable to 70–153 Vac) |
Nominal Voltage | 120 Vac (adjustable to100/120/127 Vac) |
Frequency | 50/60 Hz (auto-sensing) |
Frequency Range | 47–70 Hz (50 Hz system), 56.5–70 Hz (60 Hz system), 40 Hz in low-sensitivity mode |
Input Power Factor | 0.9 |
Electrical Output | |
Output Receptacles |
(6) NEMA 5-20R
(1) NEMA L5-30R
|
On Utility Voltage Regulation | 102–132 Vac |
On Battery Voltage Regulation | -10%, +6% of nominal |
Output Frequency | 50/60 Hz ±0.1 % (autosensing) |
Transfer Time | 1–4 ms typical |
Load Segments | Group 1: (2) 5-20R outlets Group 2: (2) 5-20R outlets view load segments application note |
Communications | |
User Interface | LCD graphical display |
LEDs | Load protected, battery and fault |
Communication Ports | 1 USB HID compliant port + 1 RS232 serial port and relay contacts (USB and RS232 ports cannot be used simultaneously) |
Communications Card Slots | 1 slot for ConnectUPS-MS network management card |
Power Management Software | Eaton Intelligent Power Software Suite CD (included) |
Environmental & Standards | |
Heat Dissipation (BTU) | Line: 305, Battery: 2047 |
Audible Noise | <50 dBA |
Operating Temperature | 0°C–40°C (32°F–104°F) |
Performance - Safety - EMC | UL1778; UL497A; cUL |
Safety markings | UL, cUL |
EMC Markings | FCC Part 15 subpart B Class A |
Storage Temperature | -15°C–50°C (5°F–122°F) |
Relative Humidity | 20–95% non-condensing |
Altitude | Up to 10,000 ft (3000m) without de-rating |
Recent News
Why Modular UPS Systems Are a Smart Power Strategy
Today’s IT environments are evolving fast. From growing server rooms to decentralized facilities, one thing remains constant—reliable, scalable power protection is essential. Traditional UPS...
How to Choose the Right UPS System for Your Business: A No-Nonsense Buyer’s Guide
Downtime is expensive. Whether you're running a data center, a healthcare facility, or a manufacturing line, power interruptions can disrupt operations and lead to major...
Hospital Emergency Backup Failures – Why Medical Facilities Can’t Afford a UPS Failure
In the high-stakes world of healthcare, seconds can save lives—or cost them. When power outages strike, hospitals and medical facilities rely heavily on uninterruptible power...