General
Topology Line-interactive
Configuration Tower
Catalog Number 5S550
UPC Number 743172 04309
Diagnostics Full system self test at power up
Dimensions (H x W x D, inches) 9.8 x 3.4 x 10.2
Dimensions (H x W x D, mm) 249 x 86 x 259
Weight (kg) 5.6
Weight (lbs) 12.3
Warranty 3 years, includes batteries
Contents
(Ships with the following items)
UPS
USB cable
User manual
Efficiency >95%
Electrical Input
Connection
(1) NEMA 5-15P

Input Cord 6 feet (1.8 meters)
Input Voltage Range 93-138 Vac
Nominal Voltage 120Vac
Operating Frequency 50/60 Hz (autosensing)
Frequency Range 46-70 Hz (50 Hz system); 57-70 Hz (60 Hz system)
 
Electrical Output
Nominal Voltage 115 Vac
Output Receptacles
(8) NEMA 5-15R

Communications
Communication Ports USB HID port as standard, 6-ft USB cable included
Power Management Software Enhance your power protection and safeguard your data when you pair it with the Eaton UPS Companion Software
 
Environmental & Standards
RoHS Compliance Yes
Surge Protection Yes. Line & network line
Audible Noise < 25 dB in normal mode
Operating Temperature 0 to 35°C (32°F to 95°F)
Performance - Safety - EMC UL 1778, UL497A
Safety markings CE / cTUVus / NOM
Storage Temperature -15°C – 40°C (5°F – 104°F)
Relative Humidity 0–90% non-condensing

Recent News

How to Choose the Right UPS System for Your Business: A No-Nonsense Buyer’s Guide

How to Choose the Right UPS System for Your Business: A No-Nonsense Buyer’s Guide

Downtime is expensive. Whether you're running a data center, a healthcare facility, or a manufacturing line, power interruptions can disrupt operations and lead to major...

Read more
Hospital Emergency Backup Failures – Why Medical Facilities Can’t Afford a UPS Failure

Hospital Emergency Backup Failures – Why Medical Facilities Can’t Afford a UPS Failure

In the high-stakes world of healthcare, seconds can save lives—or cost them. When power outages strike, hospitals and medical facilities rely heavily on uninterruptible power...

Read more
Why Your UPS Failed in a Heatwave—and How to Prevent It Next Time

Why Your UPS Failed in a Heatwave—and How to Prevent It Next Time

When temperatures soar, the last thing you want is your uninterruptible power supply (UPS) giving up on you. Yet every summer, we hear the same...

Read more