Eaton 9355 10kVA 9kW 208/208V 64-Battery 3-High 3-Phase Tower UPS
$18,859.90
Eaton 9355 10kVA 9kW 208/208V 64-Battery 3-High 3-Phase Tower UPS w/2yr Warranty
The Eaton 9355 UPS provides premium double-conversion backup power and scalable battery runtimes for IT and electrical engineering infrastructure in corporate, healthcare, banking and industrial applications. Packing maximum battery runtime into a very small footprint, the 9355 UPS is a complete three-phase power protection solution. The 9355 can be equipped with an integrated, customizable power distribution module that includes a maintenance bypass switch.
|
|
| Power | |
| Ratings (kVA/Watts) | 10 kVA/9 kW and 15 kVA/13.5 kW at 0.9 power factor |
| Topology | Double conversion |
| Electrical Input | |
| Nominal input voltage | 208V/120V or 220V/127V three-phase 400V models also available |
| Input voltage range | -15%, +10% from nominal at 100% load without depleting battery |
| Operating frequency | 50/60 Hz (45 to 65 Hz) |
| Input power factor | >0.99 typical, >0.96 frequency converter |
| Input current distortion | 5% THD |
| Electrical Output | |
| Nominal output voltage | 208/120, 220/127 Vac |
| Output voltage regulation | ±1% static; ±5% dynamic at 100% resistive load change, <1 ms response time |
| Efficiency | 91%, typical |
| Heat dissipation (BTU/hr) | 10 kVA models: 3,798 @ 208V and 220V input 6,294 @ 480V and 600V (with input isolation transformer) 15 kVA models: 5,122 @ 208V and 220V input 8,134 @ 480V and 600V (with input isolation transformer) |
| Battery | |
| Battery type | 9 Ah, sealed, lead-acid, maintenance-free |
| Battery runtime | See battery backup time chart |
| Battery management | ABM technology |
| Battery replacement | Field-replaceable |
| Charger | Default is 3.4A per battery string. Charger current is configurable from 0.5A to 25A per string with an overall maximum of 34A (limited by input current) |
| Start-on-battery | Allows start of UPS without utility input |
| General | |
| Diagnostics | Full system self-test at startup |
| UPS bypass | Automatic on overload or UPS failure |
| Parallel for redundancy | Yes, using Powerware Hot Sync technology and capacity |
| Dimensions and weights | See model selection table |
| Overload (normal operation) | 150% for 5 sec / 125% for 1 min (online), 110% for 10 min |
| Communications | |
| LCD display | Graphical LCD with blue backlight |
| LEDs | (4) LEDs for notice and alarm |
| Audible alarms | Yes |
| Communication ports | (1) RS-232, (1) relay contact, (1) REPO, (2) environmental input |
| Communication slots | (2) X-Slot communication bays |
| Power management software | Bundled Software Suite CD |
| Environmental | |
| Operating temperature | 50–104ºF (10–40ºC), 45ºC with 7.5% derating; Optimal battery performance: 77ºF (25ºC) |
| Storage temperature | 32–77ºF (0–25ºC); Recommended battery storage: 59–77ºF (15–25ºC) |
| Relative humidity | 0–95%, non-condensing |
| Audible noise | <56 dBA at 1 meter (noiseless room) typical |
| Altitude | 9,843 ft. (3000m) without derating |
| Certifications | |
| Safety certifications | UL1778 5th Edition, CSA C22.2 No. 107.3-14 |
| EMC compliance | 47 CFR Part 15/ICES-003 Class A |
| Quality | ISO 9001:2015, ISO 14001:2004 |
| Surge | ANSI C62.41 Category B3, IEC 61000-4-5 |
| Markings | cULus |
1. Due to continuous product improvements, program specifications are subject to change without notice.
Model Selection Table
| Power Rating (kVA/kW)1 |
Description | Input/Output Voltage |
Part Number2 | Base Runtime | Dimensions (HxWxD, in.) |
Weight (lb.)3 |
| 10 / 9 | 2-high w/32 battery | 208/208 | KA1011100000010 | 8 | 32.2 x 12.0 x 33.5 | 373.0 |
| 10 / 9 | 3-high w/64 battery | 208/208 | KA1012100000010 | 22 | 47.8 x 12.0 x 33.5 | 609.0 |
| 10 / 9 | 2-high w/32 battery | 220/2204 | KA1011200000010 | 8 | 32.2 x 12.0 x 33.5 | 373.0 |
| 10 / 9 | 3-high w/64 battery | 220/2204 | KA1012200000010 | 22 | 47.8 x 12.0 x 33.5 | 609.0 |
| 10 / 9 | 3-high w/32 battery and input isolation transformer | 480/208 | KA1013400000010 | 8 | 47.8 x 12.0 x 33.5 | 577.0 |
| 10 / 9 | 3-high w/32 battery and input isolation transformer | 600/208 | KA1013600000010 | 8 | 47.8 x 12.0 x 33.5 | 577.0 |
| 15 / 13.5 | 2-high w/32 battery | 208/208 | KA1511100000010 | 4 | 32.2 x 12.0 x 33.5 | 373.0 |
| 15 / 13.5 | 3-high w/64 battery | 208/208 | KA1512100000010 | 13 | 47.8 x 12.0 x 33.5 | 609.0 |
| 15 / 13.5 | 2-high w/32 battery | 220/2204 | KA1511200000010 | 4 | 32.2 x 12.0 x 33.5 | 373.0 |
| 15 / 13.5 | 3-high w/64 battery | 220/2204 | KA1512200000010 | 13 | 47.8 x 12.0 x 33.5 | 609.0 |
| 15 / 13.5 | 3-high w/32 battery and input isolation transformer | 480/208 | KA1513400000010 | 4 | 47.8 x 12.0 x 33.5 | 577.0 |
| 15 / 13.5 | 3-high w/32 battery and input isolation transformer | 600/208 | KA1513600000010 | 4 | 47.8 x 12.0 x 33.5 | 577.0 |
Recent News
Planning IT Infrastructure Growth for the 2026 New Year!
As the calendar flips toward a new year, businesses across every industry start looking ahead - evaluating what worked, what didn’t, and what needs to...
Cold Weather UPS Maintenance Tips for Data Centers and IT Infrastructure
As temperatures drop, data centers and IT facilities face new challenges that can impact the performance and reliability of their uninterruptible power supply (UPS) systems....
Lighting Inverters: Reliable Backup Power for Emergency Lighting
When power fails, lighting inverters are the unsung heroes that keep pathways illuminated, life safe, and buildings code-compliant. In this post, we’ll explain what lighting...