Eaton 9PX 9PX1000GRT 1000VA/900W 208V Online Double ConversionRack / Tower UPS
$1,229.90
Eaton 9PX 9PX1000GRT 1000VA/900W 208V Online Double Conversion Rack / Tower UPS
Eaton 9PX 9PX1000GRT Specifications:
| General | |
| Topology | Double-conversion online |
| Configuration | Rack/Tower |
| Color | Black and silver |
| Rating (VA/Watts) | 1000/900 |
| Diagnostics | Full system self test at power up and ABM test every 30 days |
| UPS Bypass | EHBPL1500R-PDU1U optional |
| Dimensions (H x W x D, inches) | 3.4 (2U) x 17.3 x 17.7 |
| Dimensions (H x W x D, mm) | 86.5 x 440 x 450 |
| Weight (kg) | 17.5 |
| Weight (lbs) | 38.6 |
| Warranty | 2 years |
| Rail Kit Included | 4-post rail kit and tower pedestals included |
| Remote Emergency Power off (REPO) | ROO/RPO: Rear deck emergency stop connectors (for remote on/off and power off) |
| Contents (Ships with the following items) |
9PX1000GRT 1000 VA UPS 4-post rail kit Safety manual User manual Tower pedestals RS-232 serial cable USB cable Intelligent Power Software Suite CD |
| Efficiency | 92.0% with resistive load |
| Electrical Input | |
| Connection | |
| Input Cord | C14 |
| Input Voltage Range | Full load: 176-276V, <40% load: 100-276V |
| Nominal Voltage | 208V default (200/208/220/230/240V) |
| Frequency | 50/60 Hz |
| Frequency Range | 60 Hz: 50–70 Hz, 50 Hz: 40–60 Hz |
| Input Power Factor | >.99 |
| Input Current Distortion | <5% |
| Electrical Output | |
| Nominal Voltage | 208V default (200/208/220/230/240V) |
| Output voltage regulation | ±1% steady-state |
| Voltage THD | <3% for linear loads |
| Output Receptacles |
(8) IEC-320-C13
|
| Transfer Time | 0 ms |
| Optional Extended Battery Module | 9PXEBM48RT |
| Battery Description | Sealed, lead-acid; maintenance free |
| Maximum number of extended battery modules (EBM) | Add up to 4 extended battery modules (EBM) |
| Battery Management | ABM technology; 3-stage charging extends battery service life by 50% and provides advance warning for battery replacement |
| Battery Replacement | Replaceable internal batteries and extended battery modules (EBMs) |
| Start On Battery | Cold-start enabled; first cold start is always forbidden |
| Communications | |
| User Interface | Graphical display. UPS status in a single view. |
| LEDs | 4 status-indicating LEDs |
| Communication Ports | RS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included |
| Power Management Software | Eaton Intelligent Power Manager |
| Environmental & Standards | |
| RoHS Compliance | Yes |
| Surge Protection | IEEE ANSI C62.41 Cat B2 |
| Heat Dissipation (BTU) | Online: 267 Battery: 438 (BTU/hr; battery full charged, resistive load) |
| Audible Noise | ≤40 dB at 1 meter |
| Operating Temperature | 0 to 40°C (32°F to 104°F) |
| Safety markings | 0 to 40°C (32°F to 104°F) |
| EMC Markings | IEC 62040-2 Class B Cat C2 / CISPR22 Class B / FCC part 15 Class B |
| Storage Temperature | 0 to 35°C (32°F to 95°F); without batteries: -15 to 55°C (5°F to 131°F) |
| Relative Humidity | 0 to 96% non-condensing |
| Altitude | 0-1500m @ 0°C - 40 °C; 1500m-3000m @ 0°C - 35 °C |
Recent News
The Real Difference Between Entry-Level, Mid-Range, and Enterprise UPS Systems
Choosing the right Uninterruptible Power Supply (UPS) isn’t just about size or price, it’s about matching the right level of protection to your...
Strategic UPS Upgrades: Strengthening Power Protection for Your Critical Operations
A reliable UPS system is more than backup power—it’s a core part of your infrastructure strategy. As power demands grow and downtime becomes more...
Planning IT Infrastructure Growth for the 2026 New Year!
As the calendar flips toward a new year, businesses across every industry start looking ahead - evaluating what worked, what didn’t, and what needs to...