





Eaton 9PX 9PX2000RTN 2000VA/1800W 120V Online Rack / Tower UPS w/Network Card
$2,049.90
Eaton 9PX 9PX2000RTN 2000VA/1800W 120V Online Rack / Tower UPS w/Net Card
Eaton 9PX 9PX2000RTN Specifications:
General | |
Topology | Double-conversion online |
Configuration | Rack/Tower |
Color | Black and silver |
Rating (VA/Watts) | 2000/1800 |
Diagnostics | Full system self test at power up and ABM test every 30 days |
UPS Bypass | Optional |
Dimensions (H x W x D, inches) | 3.4 (2U) x 17.3 x 23.8 |
Weight (lbs) | 61.5 |
Warranty | 2 years |
Rail Kit Included | 4-post rail kit and tower pedestals included |
Remote Emergency Power off (REPO) | ROO/RPO: Rear deck emergency stop connectors (for remote on/off and power off) |
Contents (Ships with the following items) |
9PX2000RTN 2000 VA UPS Gigabit Network card (Network-M2) 4-post rail kit Safety manual User manual Tower pedestals RS-232 serial cable USB cable Intelligent Power Software Suite CD |
Efficiency | 90.0% with resistive load |
Electrical Input | |
Connection |
(1) NEMA 5-20P
|
Input Cord | 8 ft |
Input Voltage Range | Full load: 100-144V, <30% load: 60-144V |
Nominal Voltage | 120V default (100/110/120/125V) |
Frequency | 50/60 Hz |
Frequency Range | 60 Hz: 50–70 Hz, 50 Hz: 40–60 Hz |
Input Power Factor | >.99 |
Input Current Distortion | <5% |
Electrical Output | |
Nominal Voltage | 120V default (100/110/120/125V) |
Output voltage regulation | ±1% steady-state |
Voltage THD | <3% for linear loads |
Output Receptacles |
(6) 5-20R, (1) L5-20R
|
Transfer Time | 0 ms |
Communications | |
User Interface | Graphical display. UPS status in a single view. |
LEDs | 4 status-indicating LEDs |
Communication Ports | RS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included |
Communications Card Slots | Network Card-MS included |
Power Management Software | Eaton Intelligent Power Manager |
Environmental & Standards | |
RoHS Compliance | Yes |
Surge Protection | IEEE ANSI C62.41 Cat B2 |
Heat Dissipation (BTU) | Online: 512 Battery: 897 (BTU/hr; battery full charged, resistive load) |
Audible Noise | ≤40 dB at 1 meter |
Operating Temperature | 0 to 40°C (32°F to 104°F) |
Safety markings | 0 to 40°C (32°F to 104°F) |
EMC Markings | IEC 62040-2 Cat C1 / CISPR22 / FCC part 15 Class B / VCCI Class B |
Storage Temperature | 0 to 35°C (32°F to 95°F); without batteries: -15 to 55°C (5°F to 131°F) |
Relative Humidity | 0 to 96% non-condensing |
Altitude | 0-1500m @ 0°C - 40 °C; 1500m-3000m @ 0°C - 35 °C |
Recent News
Lighting Inverters: Ensuring Uninterrupted Safety and Compliance for Emergency Systems
What is a Lighting Inverter? A lighting inverter converts DC battery power to standard AC voltages to provide backup for lighting systems during...
From Power Outages to Business Continuity: How UPS Systems Save the Day
Businesses can't afford unexpected power outages. Even a brief disruption can lead to lost productivity, corrupted data, and decreased customer satisfaction. That's where Uninterruptible...
Power Protection Trends for 2025
As changes in power protection continues to evolve, 2024 has brought significant shifts in the way businesses and organizations approach uninterruptible power supply (UPS) systems...