Eaton 9PX 9PX6KSP Specifications:
General | |
Topology | Double-conversion online |
Configuration | Rack/Tower |
Catalog Number | 9PX6KSP |
Color | Black and silver |
Rating (VA/Watts) | 5500/4900 |
Diagnostics | Full system self test at power up |
Dimensions (H x W x D, inches) | 6.8 (4U) x 17.3 x 25.6 |
Weight (lbs) | 157.3 |
Warranty | 2 years |
Rail Kit Included | 4-post rail kit and tower pedastals included |
Remote Emergency Power off (REPO) | ROO/RPO: Rear deck emergency stop connectors (for remote on/off and power off) |
Electrical Input | |
Connection |
(1) Terminal block with L14-30P***
|
Input Cord | 6 feet (1.8 meters) |
Input Voltage Range | Full load: 176-276V; Derating: 100-276V |
Nominal Voltage | 120/208 default (120/240, 100/200, 110/220, 115/230, 127/220) |
Frequency | 50/60 Hz |
Frequency Range | 60 Hz: 50–70 Hz, 50 Hz: 40–60 Hz |
Input Power Factor | >99 |
Input Current Distortion | <5% |
Electrical Output | |
Nominal Voltage | 120/208 default (120/240, 100/200, 110/220, 115/230, 127/220) |
Output voltage regulation | ±1% steady-state |
Voltage THD | <2% for linear loads |
Output Receptacles |
(6) NEMA 5-20R
(1) NEMA L6-30R
(1) NEMA L14-30R
Hardwired - see manual for terminal block layout
|
Power Factor | 0.9 |
Transfer Time | 0 ms |
Circuit Breaker | (4) 20A for 5-20R |
Optional Extended Battery Module | 9PXEBM240SP |
Battery Description | Sealed, lead-acid; maintenance free |
Maximum number of extended battery modules (EBM) | Add up to 4 extended battery modules (EBM) |
Battery Management | ABM technology; 3-stage charging extends battery service life by 50% and provides advance warning for battery replacement |
Battery Replacement | Hot-swappable internal batteries and extended battery modules (EBMs) |
Start On Battery | Cold-start enabled |
Communications | |
User Interface | Graphical display. UPS status in a single view. |
LEDs | 4 status-indicating LEDs |
Communication Ports | RS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included |
Communications Card Slots | Gigabit Network Card (Network-M2) included |
Power Management Software | Eaton Intelligent Power Software Suite CD (included) |
Environmental & Standards | |
RoHS Compliance | Yes |
Surge Protection | IEEE ANSI C62.41 Cat B2 |
Audible Noise | <55 dB at 1 meter |
Operating Temperature | 0 to 40°C (32°F to 104°F) |
Safety markings | CE / cULus / NOM |
EMC Markings | IEC 62040-2:2006 Cat C2 / CISPR22 Class A / FCC part 15 Class A |
Storage Temperature | 0 to 35°C (32°F to 95°F); without batteries: -15 to 60°C (5°F to 140°F) |
Relative Humidity | 0 to 95% |
Altitude | <3,000m for nominal power; -5°C temp derating every 500m |
Recent News
Why Modular UPS Systems Are a Smart Power Strategy
Today’s IT environments are evolving fast. From growing server rooms to decentralized facilities, one thing remains constant—reliable, scalable power protection is essential. Traditional UPS...
How to Choose the Right UPS System for Your Business: A No-Nonsense Buyer’s Guide
Downtime is expensive. Whether you're running a data center, a healthcare facility, or a manufacturing line, power interruptions can disrupt operations and lead to major...
Hospital Emergency Backup Failures – Why Medical Facilities Can’t Afford a UPS Failure
In the high-stakes world of healthcare, seconds can save lives—or cost them. When power outages strike, hospitals and medical facilities rely heavily on uninterruptible power...