Eaton 9PX 9PX700RT Specifications:
General | |
Topology | Double-conversion online |
Configuration | Rack/Tower |
Catalog Number | 9PX700RT |
Color | Black and silver |
Rating (VA/Watts) | 700/630 |
Diagnostics | Full system self test at power up and ABM test every 30 days |
UPS Bypass | EHBPL1500R-PDU1U optional |
Dimensions (H x W x D, inches) | 3.4 (2U) x 17.3 x 17.7 |
Dimensions (H x W x D, mm) | 86.5 x 440 x 450 |
Weight (kg) | 16.5 |
Weight (lbs) | 36.4 |
Warranty | 2 years |
Rail Kit Included | 4-post rail kit and tower pedestals included |
Remote Emergency Power off (REPO) | ROO/RPO: Rear deck emergency stop connectors (for remote on/off and power off) |
Contents (Ships with the following items) |
9PX700RT 700 VA UPS 4-post rail kit Safety manual User manual Tower pedestals RS-232 serial cable USB cable Intelligent Power Software Suite CD |
Efficiency | 89.9% with resistive load |
Electrical Input | |
Connection |
(1) NEMA 5-15P
|
Input Cord | 8 feet |
Input Voltage Range | Full load: 100-144V, <30% load: 60-144V |
Nominal Voltage | 120V default (100/110/120/125V) |
Frequency | 50/60 Hz |
Frequency Range | 60 Hz: 50–70 Hz, 50 Hz: 40–60 Hz |
Input Power Factor | >.99 |
Input Current Distortion | <5% |
Electrical Output | |
Nominal Voltage | 120V default (100/110/120/125V) |
Output voltage regulation | ±1% steady-state |
Voltage THD | <3% for linear loads |
Output Receptacles |
(8) NEMA 5-15R
|
Transfer Time | 0 ms |
Communications | |
User Interface | Graphical display. UPS status in a single view. |
LEDs | 4 status-indicating LEDs |
Communication Ports | RS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included |
Power Management Software | Eaton Intelligent Power Manager |
Environmental & Standards | |
RoHS Compliance | Yes |
Surge Protection | IEEE ANSI C62.41 Cat B2 |
Heat Dissipation (BTU) | Online: 241 Battery: 440 (BTU/hr; battery full charged, resistive load) |
Audible Noise | ≤40 dB at 1 meter |
Operating Temperature | 0 to 40°C (32°F to 104°F) |
Safety markings | 0 to 40°C (32°F to 104°F) |
EMC Markings | IEC 62040-2 Cat C1 / CISPR22 / FCC part 15 Class B / VCCI Class B |
Storage Temperature | 0 to 35°C (32°F to 95°F); without batteries: -15 to 55°C (5°F to 131°F) |
Relative Humidity | 0 to 96% non-condensing |
Altitude | 0-1500m @ 0°C - 40 °C; 1500m-3000m @ 0°C - 35 °C |
Recent News
Why Modular UPS Systems Are a Smart Power Strategy
Today’s IT environments are evolving fast. From growing server rooms to decentralized facilities, one thing remains constant—reliable, scalable power protection is essential. Traditional UPS...
How to Choose the Right UPS System for Your Business: A No-Nonsense Buyer’s Guide
Downtime is expensive. Whether you're running a data center, a healthcare facility, or a manufacturing line, power interruptions can disrupt operations and lead to major...
Hospital Emergency Backup Failures – Why Medical Facilities Can’t Afford a UPS Failure
In the high-stakes world of healthcare, seconds can save lives—or cost them. When power outages strike, hospitals and medical facilities rely heavily on uninterruptible power...