GE VH Series 25513 2000VA/1740W 120V Online Double Conversion Rack /Tower UPS

$1,349.90
Adding to Cart Added to Cart
GE VH Series 25513 2000VA/1740W 120V Online Double Conversion Rack /Tower UPS

Double Conversion UPS, Rack/Tower Mounting, 1kVA VA Rating, 900W Watts, 120VAC Input Voltage, 50/60 Hz, Input Current 9.1A, Output Voltage 100/110/115/120/127VAC, 1 Phase, Backup Time (Half/Full Load) 18 min./8 min., Number of Outlets (6) 5-15R, Outlet Type (6) UPS/Surge, Automatic Volts Regulation Yes, Fax/Modem Line Protection No, Transfer Time 1 msec, Height 3.4 In., Depth 18.6 In., Width 17.3 In., Input Connection 3 ft. Cord with NEMA 5-15P Plug, Ports USB & RJ11


Technical Specs

  • ItemDouble Conversion UPS
  • UPS TypeOn-Line/Double Conversion
  • VA Rating - UPS Systems2kVA
  • Watts - UPS Systems1.74kW
  • Input Voltage - UPS Systems120VAC
  • Output Voltage - UPS Systems100VAC, 110VAC, 115VAC, 120VAC, 127VAC
  • Backup Time (Half/Full Load)18 min./8 min.
  • Mounting - UPS SystemsRack/Tower
  • Outlet Type - UPS SystemsUPS/Surge
  • Number of Outlets7
  • Medical GradeNo
  • NEMA Receptacle Configuration5-20R, L5-20R
  • NEMA Plug Configuration5-20P
  • Automatic Volts RegulationYes
  • Fax/Modem Line ProtectionNo
  • Transfer Time1 msec
  • Width17.3"
  • Depth21.5"
  • Height3.4"
  • Cord Length3 ft.
  • Display TypeLED
  • Hz50/60
  • Input Current16A
  • Phase1
  • PortsRS232, USB, Relay
  • Special FeaturesFailsafe Bypass
  • StandardsUL1778, 4th edition, EN62040-2
  • IncludesAutomatic Shutdown Software

    Recent News

    Why Does Room Temperature Have Such a Big Impact on UPS Battery Life?

    Why Does Room Temperature Have Such a Big Impact on UPS Battery Life?

    When it comes to protecting critical equipment, most people focus on the UPS itself, its capacity, runtime, and features. However, one of the biggest factors...

    Read more
    Single-Phase vs. Three-Phase UPS: What Growing Businesses Get Wrong

    Single-Phase vs. Three-Phase UPS: What Growing Businesses Get Wrong

    As businesses grow, so do their power demands. What once worked for a small server room or office network can quickly become inadequate as more...

    Read more
    How Heat Affects Data Centers and Why Your UPS System Is at Risk

    How Heat Affects Data Centers and Why Your UPS System Is at Risk

    As temperatures rise and computing demands continue to grow, heat has become one of the most serious threats facing modern data centers, server rooms, and...

    Read more