  • GXT4-1500RT120 - Liebert GXT4 1500VA Specifications:

    Output:

    Output power capacity

    1350 Watts / 1500VA

    Max Configurable Power

    1350 Watts / 1500VA

    Nominal output voltage

    120V

    Output Voltage Distortion

    less than 3% at full load

    Output Frequency (sync to mains)

    40 - 70 Hz for 60 Hz nominal

    Waveform type

    Sine wave

    Output Connections

    (6) NEMA 5-15R



    Input:

    Nominal input voltage

    120V

    Input frequency

    40/70 Hz +/- 3 Hz (auto sensing)

    Input Connection Type

    NEMA 5-15P


    Cord Length

    10 feet (3.04 meters)

    Input voltage range for main operations

    60 - 140V


    Batteries and Runtime:

    Battery type

    Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof

    Typical backup time at half load

    16 minutes (675 Watts)

    Typical backup time at full load

    5 minutes (1350 Watts)


    Communications and Management:

    Interface port

    IntelliSlot , USB

    Available IntelliSlot Interface Quantity

    1


    Physical:

    Maximum height

    3.3 inches (83 mm)

    Maximum width

    16.9 inches (429 mm)

    Maximum depth

    19.6 inches (497 mm)

    Net weight

    54.67 lbs. (24.79 kg)

    Shipping Weight

    69.7 lbs. (31.61 kg)

    Rack Height

    2U

  • Recent News

    Why Does Room Temperature Have Such a Big Impact on UPS Battery Life?

    Why Does Room Temperature Have Such a Big Impact on UPS Battery Life?

    When it comes to protecting critical equipment, most people focus on the UPS itself, its capacity, runtime, and features. However, one of the biggest factors...

    Read more
    Single-Phase vs. Three-Phase UPS: What Growing Businesses Get Wrong

    Single-Phase vs. Three-Phase UPS: What Growing Businesses Get Wrong

    As businesses grow, so do their power demands. What once worked for a small server room or office network can quickly become inadequate as more...

    Read more
    How Heat Affects Data Centers and Why Your UPS System Is at Risk

    How Heat Affects Data Centers and Why Your UPS System Is at Risk

    As temperatures rise and computing demands continue to grow, heat has become one of the most serious threats facing modern data centers, server rooms, and...

    Read more