Liebert GXT4-1500RT120 1500VA / 1350W 120V Online UPS System

$674.99

Item is out of stock

Adding to Cart Added to Cart

Liebert GXT4-1500RT120 1500VA / 1350W 120V Online UPS System - New Battery


Professionally re-certified with new batteries installed. Includes no mounting hardware or communication options. May show minor signs of wear consistent with previous installation.



  • GXT4-1500RT120 - Liebert GXT4 1500VA Specifications:

    Output:

    Output power capacity

    1350 Watts / 1500VA

    Max Configurable Power

    1350 Watts / 1500VA

    Nominal output voltage

    120V

    Output Voltage Distortion

    less than 3% at full load

    Output Frequency (sync to mains)

    40 - 70 Hz for 60 Hz nominal

    Waveform type

    Sine wave

    Output Connections

    (6) NEMA 5-15R



    Input:

    Nominal input voltage

    120V

    Input frequency

    40/70 Hz +/- 3 Hz (auto sensing)

    Input Connection Type

    NEMA 5-15P


    Cord Length

    10 feet (3.04 meters)

    Input voltage range for main operations

    60 - 140V


    Batteries and Runtime:

    Battery type

    Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof

    Typical backup time at half load

    16 minutes (675 Watts)

    Typical backup time at full load

    5 minutes (1350 Watts)


    Communications and Management:

    Interface port

    IntelliSlot , USB

    Available IntelliSlot Interface Quantity

    1


    Physical:

    Maximum height

    3.3 inches (83 mm)

    Maximum width

    16.9 inches (429 mm)

    Maximum depth

    19.6 inches (497 mm)

    Net weight

    54.67 lbs. (24.79 kg)

    Shipping Weight

    69.7 lbs. (31.61 kg)

    Rack Height

    2U

  • Recent News

    Spring Facility Check: Don’t Forget Your Lighting Inverter

    Spring Facility Check: Don’t Forget Your Lighting Inverter

      As winter begins to fade and facilities start their spring maintenance routines, many teams focus on HVAC systems, generators, and electrical inspections. While these...

    Read more
    AI Is Changing Power Demands: Is Your UPS Infrastructure Ready?

    AI Is Changing Power Demands: Is Your UPS Infrastructure Ready?

     {"height":13,"color":{"hue":213,"brightness":0.83,"saturation":1,"alpha":0},"hidden":false,"locked":false,"blockName":"Spacer"} Artificial intelligence isn’t just impacting hyperscale data centers. It’s changing power infrastructure requirements across mid-sized data centers, healthcare facilities, manufacturing plants, and enterprise IT...

    Read more
    The Real Difference Between Entry-Level, Mid-Range, and Enterprise UPS Systems

    The Real Difference Between Entry-Level, Mid-Range, and Enterprise UPS Systems

        Choosing the right Uninterruptible Power Supply (UPS) isn’t just about size or price, it’s about matching the right level of protection to your...

    Read more