N1 Critical N1C.L3000 3000VA/2700W 120V Lithium Ion Rack/Tower UPS

$3,174.90

Only 5 left in stock

Adding to Cart Added to Cart
The N1C.L3000 UPS is the longest-running internal battery 3000VA, 120-volt, rack-mount model UPS in the market.
Main Features of the N1C.L3000VA UPS:

 

  • 3 KVA
  • 120VAC
  • Rack and Tower Mountable
  • Standard with SNMP Communication Port and 1000 Node Software Suite
  • 13 Minutes of back up time at 100% load. 3X more than Lead Acid
  • Rack Rails Included
  • The Industry’s ONLY 10-Year Warranty

Specifications for the N1C.L3000VA UPS:


INPUT

  • Voltage (Vac): 110/120±2%
  • Frequency (Hz): 50/60±5% (±10% is selectable)
  • Power Factor: 0.9

OUTPUT

  • Capacity (VA/W): 3000/2700
  • Voltage (Vac): 110/120±2%
  • Frequency (Hz): 50/60±2% (battery mode)
  • Waveform: Sine wave, THD<3% at linear load
  • Transfer time: 0ms
  • Overload: 105%~129% for 60 seconds, 130%~150% for 30 seconds, above 150% for 300ms
  • Input connection: L5-30P
  • NEMA Outlets: (4) 5-15/20R, (1) L5-30R

BATTERY

  • Voltage (Vdc): 72
  • Run Time at 100%/50% Load (minutes): 11/24
  • Charger Current (A): 4A, battery monitoring system included

OTHER:

  • Communications Interface: USB, EPO and SNMP/Network Card
  • Topology: Online Double Conversion
  • Alarm: Low battery, abnormal AC input, UPS failure
  • Protection: Low Battery, overload, short-circuit, over temperature
  • Working Temperature: 32º-140º
  • Relative Humidity: 0~95%, no condensation
  • Dimensions (HxWxD) (in): 3.4″(2U)x17.2″x22.4″
  • Net Weight (lb): 55

Recent News

Strategic UPS Upgrades: Strengthening Power Protection for Your Critical Operations

Strategic UPS Upgrades: Strengthening Power Protection for Your Critical Operations

  A reliable UPS system is more than backup power—it’s a core part of your infrastructure strategy. As power demands grow and downtime becomes more...

Read more
Planning IT Infrastructure Growth for the 2026 New Year!

Planning IT Infrastructure Growth for the 2026 New Year!

As the calendar flips toward a new year, businesses across every industry start looking ahead - evaluating what worked, what didn’t, and what needs to...

Read more
Cold Weather UPS Maintenance Tips for Data Centers and IT Infrastructure

Cold Weather UPS Maintenance Tips for Data Centers and IT Infrastructure

As temperatures drop, data centers and IT facilities face new challenges that can impact the performance and reliability of their uninterruptible power supply (UPS) systems....

Read more