Riello Guard Tower 10kVA / 10kW 208/240V Hardwired In/Out Online Tower UPS (GTT-10000)
Guard Tower is the ideal solution for protecting mission-critical systems such as safety devices, telecommunications equipment and IT systems to ensure maximum power reliability.
Guard Tower is designed and built using state-of-the-art technology and components to provide maximum protection to the powered loads with no impact on downstream systems and optimized energy savings. The series includes 6-10 kVA/kW single/single-phase output models with ON LINE double conversion technology (VFI): the load is powered continuously by the inverter which supplies a sinusoidal voltage, filtered and stabilize in terms of form and frequency.
Highlights
- Power Rating: 10 kVA
- Unity Power Factor!
- Topology: True on-line double conversion
- Total microprocessor and DSP control
- Output terminal board
- High overload capacity
- Multi-platform communication for all operating systems
- 2-Year Warranty
Technical Specs
| Model Number | GTT-10000 |
| Capacity (kVA/kW) | 10kVA/10KW |
| Topology | True On-Line, Double-Conversion |
Input
| Rated Voltage [V] |
208 / 220 / 230 / 240 |
| Voltage Tolerance |
10 <Vin <300 @ 60% LOAD / 176 <Vin <300 @ 100% Load |
| Phase | 1PH |
| Frequency | 50/60HZ |
| Power Factor | >0.99 |
| DC Voltage | 240 VDC |
Output
| Rated Power [kVA] |
10 |
| Active Power [kW] |
10 |
| Voltage [V] option UPS |
240 plus neutral for a split of 120/120 or 230 plus neutral for a split 115/115 |
| Number Phases |
1 |
| Waveform |
Sinewave |
| Frequency [Hz] |
Can be selected: 60 or self-learning |
Environment
| Operating Temperature |
32 – 104 °F / 0 – 40 °C |
| Humidity | <95% without condensation |
| Communications |
USB / DB9 with RS232 and contacts / Slot for communication interface |
| Safety Compiance | UL1778:2014 and CSA C22.2 No. 107.3-14 |
| Certification |
Certified by TUV per UL 1778 |
| Accessories Provided |
Power cable, serial cable, USB cable, safety manual, quick start, software downloadable |
| Audible Noise | <55 dB(A) at 3.3 ft / 1 m |
Dimensions
| Dimensions | 9.84 x 24.80 x 32.44 inches |
| Weight | 313 lbs. |
Recent News
Single-Phase vs. Three-Phase UPS: What Growing Businesses Get Wrong
As businesses grow, so do their power demands. What once worked for a small server room or office network can quickly become inadequate as more...
How Heat Affects Data Centers and Why Your UPS System Is at Risk
As temperatures rise and computing demands continue to grow, heat has become one of the most serious threats facing modern data centers, server rooms, and...
Spring Facility Check: Don’t Forget Your Lighting Inverter
As winter begins to fade and facilities start their spring maintenance routines, many teams focus on HVAC systems, generators, and electrical inspections. While these...