*Preowned* Tripp Lite Smart Online 5kVA 4.5 kW Double Conversion UPS (SU5000RT4UHV)

The SU5000RT4UHV 5000VA/4500W on-line, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a single 4U rack/tower compatible housing

Highlights:
  • 5kVA / 5000VA / 4500W on-line double-conversion UPS; 0.9 power factor
  • 200/208/220/230/240V 50/60Hzoutput; high efficiency economy mode option
  • 4U Rack/Tower compatible; Hot- swappable batteries; Expandable runtime
  • USB, RS232 & EPO ports; Slot for network management card options
  • Front panel LEDs with detailed LCD monitoring and control screen
  • ENERGY STAR Version 2.0 qualified
  • NEMA L6-30P input (3 wire); L6-30R & L6-20R outputs
Specifications:
UPC code
037332146823
UPS type
Online
Rated input current (max)
24A
Nominal input voltage
208V
Input connection
L6-30P
Input circuit breakers
20A
Cord length
10ft
Phase
Single-phase
Output capacity
5000VA/4500W
Power factor 0.9
Crest factor
3:1
Frequency
50/60 Hz
Output connections (2) L6-20R; (2) L6-30R
Waveform
Pure sign wave
Battery type
Valve Regulated Lead Acid (VRLA)
Runtime Full Load (min.) 3.5 min. (1350W)
Runtime Half Load (min.) 11 min. (675W)
Expandable runtime
yes
DC system voltage 192VDC
Weight
113.6lbs
Dimensions (HxWxD)
6.85 x 17.5 x 20.67 in

 

NOTES: 

System retired from functional setting and may show signs of wear consistent with previous installation/removal.

System has been professionally tested & load banked for functionality.

NEW Batteries installed

Due to multiple units being available - serial number and data tag of unit purchased may be different than pictured

Recent News

Single-Phase vs. Three-Phase UPS: What Growing Businesses Get Wrong

Single-Phase vs. Three-Phase UPS: What Growing Businesses Get Wrong

As businesses grow, so do their power demands. What once worked for a small server room or office network can quickly become inadequate as more...

Read more
How Heat Affects Data Centers and Why Your UPS System Is at Risk

How Heat Affects Data Centers and Why Your UPS System Is at Risk

As temperatures rise and computing demands continue to grow, heat has become one of the most serious threats facing modern data centers, server rooms, and...

Read more
Spring Facility Check: Don’t Forget Your Lighting Inverter

Spring Facility Check: Don’t Forget Your Lighting Inverter

  As winter begins to fade and facilities start their spring maintenance routines, many teams focus on HVAC systems, generators, and electrical inspections. While these...

Read more