TrippLite Smart Online 5kVA 4.5 kW Double Conversion UPS (SU5000RT4UHV)
*Preowned* Tripp Lite Smart Online 5kVA 4.5 kW Double Conversion UPS (SU5000RT4UHV)
The SU5000RT4UHV 5000VA/4500W on-line, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a single 4U rack/tower compatible housing
Highlights:
- 5kVA / 5000VA / 4500W on-line double-conversion UPS; 0.9 power factor
- 200/208/220/230/240V 50/60Hzoutput; high efficiency economy mode option
- 4U Rack/Tower compatible; Hot- swappable batteries; Expandable runtime
- USB, RS232 & EPO ports; Slot for network management card options
- Front panel LEDs with detailed LCD monitoring and control screen
- ENERGY STAR Version 2.0 qualified
- NEMA L6-30P input (3 wire); L6-30R & L6-20R outputs
Specifications:
UPC code |
037332146823 |
UPS type |
Online |
Rated input current (max) |
24A |
Nominal input voltage |
208V |
Input connection |
L6-30P |
Input circuit breakers |
20A |
Cord length |
10ft |
Phase |
Single-phase |
Output capacity |
5000VA/4500W |
Power factor | 0.9 |
Crest factor |
3:1 |
Frequency |
50/60 Hz |
Output connections | (2) L6-20R; (2) L6-30R |
Waveform |
Pure sign wave |
Battery type |
Valve Regulated Lead Acid (VRLA) |
Runtime Full Load (min.) | 3.5 min. (1350W) |
Runtime Half Load (min.) | 11 min. (675W) |
Expandable runtime |
yes |
DC system voltage | 192VDC |
Weight |
113.6lbs |
Dimensions (HxWxD) |
6.85 x 17.5 x 20.67 in |
NOTES:
System retired from functional setting and may show signs of wear consistent with previous installation/removal.
System has been professionally tested & load banked for functionality.
NEW Batteries installed
Due to multiple units being available - serial number and data tag of unit purchased may be different than pictured
Recent News
Why Modular UPS Systems Are a Smart Power Strategy
Today’s IT environments are evolving fast. From growing server rooms to decentralized facilities, one thing remains constant—reliable, scalable power protection is essential. Traditional UPS...
How to Choose the Right UPS System for Your Business: A No-Nonsense Buyer’s Guide
Downtime is expensive. Whether you're running a data center, a healthcare facility, or a manufacturing line, power interruptions can disrupt operations and lead to major...
Hospital Emergency Backup Failures – Why Medical Facilities Can’t Afford a UPS Failure
In the high-stakes world of healthcare, seconds can save lives—or cost them. When power outages strike, hospitals and medical facilities rely heavily on uninterruptible power...