TrippLite Smart Online 5kVA 4.5 kW Double Conversion UPS (SU5000RT4UHV)
*Preowned* Tripp Lite Smart Online 5kVA 4.5 kW Double Conversion UPS (SU5000RT4UHV)
The SU5000RT4UHV 5000VA/4500W on-line, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a single 4U rack/tower compatible housing
Highlights:
- 5kVA / 5000VA / 4500W on-line double-conversion UPS; 0.9 power factor
- 200/208/220/230/240V 50/60Hzoutput; high efficiency economy mode option
- 4U Rack/Tower compatible; Hot- swappable batteries; Expandable runtime
- USB, RS232 & EPO ports; Slot for network management card options
- Front panel LEDs with detailed LCD monitoring and control screen
- ENERGY STAR Version 2.0 qualified
- NEMA L6-30P input (3 wire); L6-30R & L6-20R outputs
Specifications:
| UPC code |
037332146823 |
| UPS type |
Online |
| Rated input current (max) |
24A |
| Nominal input voltage |
208V |
| Input connection |
L6-30P |
| Input circuit breakers |
20A |
| Cord length |
10ft |
| Phase |
Single-phase |
| Output capacity |
5000VA/4500W |
| Power factor | 0.9 |
| Crest factor |
3:1 |
| Frequency |
50/60 Hz |
| Output connections | (2) L6-20R; (2) L6-30R |
| Waveform |
Pure sign wave |
| Battery type |
Valve Regulated Lead Acid (VRLA) |
| Runtime Full Load (min.) | 3.5 min. (1350W) |
| Runtime Half Load (min.) | 11 min. (675W) |
| Expandable runtime |
yes |
| DC system voltage | 192VDC |
| Weight |
113.6lbs |
| Dimensions (HxWxD) |
6.85 x 17.5 x 20.67 in |
NOTES:
System retired from functional setting and may show signs of wear consistent with previous installation/removal.
System has been professionally tested & load banked for functionality.
NEW Batteries installed
Due to multiple units being available - serial number and data tag of unit purchased may be different than pictured
Recent News
Single-Phase vs. Three-Phase UPS: What Growing Businesses Get Wrong
As businesses grow, so do their power demands. What once worked for a small server room or office network can quickly become inadequate as more...
How Heat Affects Data Centers and Why Your UPS System Is at Risk
As temperatures rise and computing demands continue to grow, heat has become one of the most serious threats facing modern data centers, server rooms, and...
Spring Facility Check: Don’t Forget Your Lighting Inverter
As winter begins to fade and facilities start their spring maintenance routines, many teams focus on HVAC systems, generators, and electrical inspections. While these...