Tripp-Lite Smart Online SU3000RTXL3U 3000VA 2400W 120V 3U UPS
OUTPUT
| Output Volt Amp Capacity (VA) | 3000 |
| Output kVA Capacity (kVA) | 3 |
| Output Watt Capacity (Watts) | 2400 |
| Output kW Capacity (kW) | 2.4 |
| Power Factor | 0.8 |
| Crest Factor | 3:1 |
| Nominal Voltage Details | 120V default |
| Frequency Compatibility | 50 / 60 Hz |
| Frequency Compatibility Details | Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start |
| Output Voltage Regulation (Line Mode) | +/- 2% |
| Output Voltage Regulation (Economy Line Mode) | +/- 10% |
| Output Voltage Regulation (Battery Mode) | +/- 2% |
| Load Management Receptacles | Two switchable four-outlet load banks, (bank 1 - four 5-15/20R, bank 2 - four 5-15R outlets) |
| Output Circuit Breakers | 15A branch rated (x2) - each breaker protects 4 outlets, L5-30R is unbreakered |
| Output AC Waveform (AC Mode) | Pure Sine wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Output Capacity Details | OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits) |
| Nominal Output Voltage(s) Supported | 110V; 120V |
| Output Receptacles | (4) 5-15R; (4) 5-15/20R; (1) L5-30R |
| Individually Controllable Load Banks | Yes |
INPUT
| Rated input current (Maximum Load) | 24A |
| Nominal Input Voltage(s) Supported | 110V AC; 120V AC |
| UPS Input Connection Type | L5-30P |
| Input Circuit Breakers | 40A |
| UPS Input Cord Length (ft.) | 10 |
| Recommended Electrical Service | 30A 120V |
| Input Phase | Single-Phase |
Save 10% on Your First Order
Join our email list for exclusive pricing, product updates, and offers built for your business. We'll only send what's useful, never spam.
New subscribers get 10% off their first order—up to $250.
Recent News
Why Runtime Isn't the Only Thing That Matters When Buying a UPS
Learn why UPS runtime is only one factor when buying a battery backup. Discover how sizing, battery technology, reliability, and power quality affect your UPS...
Why Does Room Temperature Have Such a Big Impact on UPS Battery Life?
When it comes to protecting critical equipment, most people focus on the UPS itself, its capacity, runtime, and features. However, one of the biggest factors...
Single-Phase vs. Three-Phase UPS: What Growing Businesses Get Wrong
As businesses grow, so do their power demands. What once worked for a small server room or office network can quickly become inadequate as more...