Tripp-Lite Smart Online SU3000RTXL3U 3000VA 2400W 120V 3U UPS
$599.99
Tripp-Lite Smart Online SU3000RTXL3U 3000VA 2400W 120V 3U UPS
Professionally re-certified with new batteries installed. Includes no mounting hardware or communication options. May show minor signs of wear consistent with previous installation.
OUTPUT
Output Volt Amp Capacity (VA) | 3000 |
Output kVA Capacity (kVA) | 3 |
Output Watt Capacity (Watts) | 2400 |
Output kW Capacity (kW) | 2.4 |
Power Factor | 0.8 |
Crest Factor | 3:1 |
Nominal Voltage Details | 120V default |
Frequency Compatibility | 50 / 60 Hz |
Frequency Compatibility Details | Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start |
Output Voltage Regulation (Line Mode) | +/- 2% |
Output Voltage Regulation (Economy Line Mode) | +/- 10% |
Output Voltage Regulation (Battery Mode) | +/- 2% |
Load Management Receptacles | Two switchable four-outlet load banks, (bank 1 - four 5-15/20R, bank 2 - four 5-15R outlets) |
Output Circuit Breakers | 15A branch rated (x2) - each breaker protects 4 outlets, L5-30R is unbreakered |
Output AC Waveform (AC Mode) | Pure Sine wave |
Output AC Waveform (Battery Mode) | Pure Sine wave |
Output Capacity Details | OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits) |
Nominal Output Voltage(s) Supported | 110V; 120V |
Output Receptacles | (4) 5-15R; (4) 5-15/20R; (1) L5-30R |
Individually Controllable Load Banks | Yes |
INPUT
Rated input current (Maximum Load) | 24A |
Nominal Input Voltage(s) Supported | 110V AC; 120V AC |
UPS Input Connection Type | L5-30P |
Input Circuit Breakers | 40A |
UPS Input Cord Length (ft.) | 10 |
Recommended Electrical Service | 30A 120V |
Input Phase | Single-Phase |
Recent News
Why Modular UPS Systems Are a Smart Power Strategy
Today’s IT environments are evolving fast. From growing server rooms to decentralized facilities, one thing remains constant—reliable, scalable power protection is essential. Traditional UPS...
How to Choose the Right UPS System for Your Business: A No-Nonsense Buyer’s Guide
Downtime is expensive. Whether you're running a data center, a healthcare facility, or a manufacturing line, power interruptions can disrupt operations and lead to major...
Hospital Emergency Backup Failures – Why Medical Facilities Can’t Afford a UPS Failure
In the high-stakes world of healthcare, seconds can save lives—or cost them. When power outages strike, hospitals and medical facilities rely heavily on uninterruptible power...