Tripp-Lite Smart Online SU3000RTXL3U 3000VA 2400W 120V 3U UPS
$599.99
Tripp-Lite Smart Online SU3000RTXL3U 3000VA 2400W 120V 3U UPS
Professionally re-certified with new batteries installed. Includes no mounting hardware or communication options. May show minor signs of wear consistent with previous installation.
OUTPUT
| Output Volt Amp Capacity (VA) | 3000 |
| Output kVA Capacity (kVA) | 3 |
| Output Watt Capacity (Watts) | 2400 |
| Output kW Capacity (kW) | 2.4 |
| Power Factor | 0.8 |
| Crest Factor | 3:1 |
| Nominal Voltage Details | 120V default |
| Frequency Compatibility | 50 / 60 Hz |
| Frequency Compatibility Details | Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start |
| Output Voltage Regulation (Line Mode) | +/- 2% |
| Output Voltage Regulation (Economy Line Mode) | +/- 10% |
| Output Voltage Regulation (Battery Mode) | +/- 2% |
| Load Management Receptacles | Two switchable four-outlet load banks, (bank 1 - four 5-15/20R, bank 2 - four 5-15R outlets) |
| Output Circuit Breakers | 15A branch rated (x2) - each breaker protects 4 outlets, L5-30R is unbreakered |
| Output AC Waveform (AC Mode) | Pure Sine wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Output Capacity Details | OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits) |
| Nominal Output Voltage(s) Supported | 110V; 120V |
| Output Receptacles | (4) 5-15R; (4) 5-15/20R; (1) L5-30R |
| Individually Controllable Load Banks | Yes |
INPUT
| Rated input current (Maximum Load) | 24A |
| Nominal Input Voltage(s) Supported | 110V AC; 120V AC |
| UPS Input Connection Type | L5-30P |
| Input Circuit Breakers | 40A |
| UPS Input Cord Length (ft.) | 10 |
| Recommended Electrical Service | 30A 120V |
| Input Phase | Single-Phase |
Recent News
Single-Phase vs. Three-Phase UPS: What Growing Businesses Get Wrong
As businesses grow, so do their power demands. What once worked for a small server room or office network can quickly become inadequate as more...
How Heat Affects Data Centers and Why Your UPS System Is at Risk
As temperatures rise and computing demands continue to grow, heat has become one of the most serious threats facing modern data centers, server rooms, and...
Spring Facility Check: Don’t Forget Your Lighting Inverter
As winter begins to fade and facilities start their spring maintenance routines, many teams focus on HVAC systems, generators, and electrical inspections. While these...